Optional accessories – Temco Tool 39RDVDSN User Manual

Page 34

Advertising
background image

34

RDVDSN Series Direct Vent Gas Fireplace

20007894

FK24 Fan Assembly

This auxiliary fan system increases the efficiency of the
circulation of the heating air.
The FK24 fan kit allows variable speed control of the
circulation fan and also incorporates a heat sensor in
the circuit.
Specifications
115 Volt / 60Hz / 56 Watts
Maintenance
The fan itself does not require regular maintenance,
however periodic cleaning of the fan and the
surrounding area is required.
Check the area under the control door (lower louvre
assembly) and in front of the fan and wipe or vacuum this
area at least once a month during the operating season.
Installation
The fan assembly and other components are supplied
fully wired eliminating the need for a licensed electrician
to carry out the installation.
If hard wiring the fan using Method B (following), we
strongly recommend the use of a licensed electrician.
1. Open the lower louvre assembly. Maneuver the fan

& bracket assembly around the gas valve and lines
to locate the unit onto the screw studs on the back of
the fireplace.

2. Install the thermal sensor under the bottom of the of

the firebox, locating it over the two 10 mm studs and
secure it with nuts.

3. Locate the fan speed control unit. This can be fitted

behind the lower louvre assembly as in Figure 52
or located remotely in a conveniently located wall
mounted electrical box. Remote location of the
speed control will require suitable extension of the
component wiring.

4. The power supply may be connected in two ways:
Method A
Route the 6’ lead fitted to the unit to a conveniently

located wall socket.

Method B (Using EB-1 Receptacle Box)
The EB-1 receptacle box (Pt. # ZA1200) may be

hard wired into the house supply. The fan lead is
then plugged into the EB-1 box. For instruction on
wiring the EB-1 Electrical Junction Box see the
earlier chapter in the Installation section of this
manual.

FK12
This auxiliary fan system increases the efficiency of the
circulation of the heating air.
The FK12 Fan Assembly is a fixed speed fan system
and does not allow for variable speed control. It does
not use the speed control unit or the heat sensor used
in the FK24 Kit.
Specifications
115 Volts / 60 Hz / 56 Watts.
Maintenance
The fan itself does not require regular maintenance,
however periodic cleaning of the fan and the
surrounding area is required.
Check the area under the control door (lower louvre
assembly) and in front of the fan and wipe or vacuum this
area at least once a month during the operating season.
Installation
The fan assembly is supplied fully wired eliminating the
need for a licensed electrician to carry out the installation.
1. Open the lower Louvre assembly. Maneuver the

fan & bracket assembly around the gas valve and
lines to locate the unit against the back wall of the
appliance, resting on the base.

2. With the protective cover removed from the self-

adhesive ‘Velcro’ strips apply mild pressure to the
fan & bracket unit to secure the strips to the metal
panels. No further securing is required.

3. Power to the fan can be supplied by plugging the

supplied lead into a conveniently located wall socket
or by using a hard-wired EB-1 connector box.

Optional Accessories

Fan Kits

FP1230

FK24

fan install

11/02

Thermal Sen-

sor

Fan Speed

Switch

Gas

Lines

EB-1

Receptacle

Box

Fan

FP1230

Fig. 52 FK24 fan placement.

Advertising
This manual is related to the following products: