SECTION 3: SITE PREPARATION

BUILT-IN INSTALLATIONS

All Char-Glo

®

Outdoor Barbecues

are CGA and AGA approved.

Note: All height width and depth dimensions are shown in inches.

Determine a suitable location for the barbecue by taking into account exposure to wind and availability of gas and
electrical supplies. Exposure to wind should be minimized, as wind can adversely affect cooking performance. Insure
that the gas supply line and electrical supply are located in close proximity to the unit to keep connections to the
unit as short as possible and allow for installation and removal of the unit from the enclosure. Allow adequate area
around the unit for dissipation of smoke produced during cooking.

CLEARANCES (Refer to Figures 3 and 4)

CABINET PREPARATION

The models CGBD30, CGBD36 and CGBD48 are designed for easy installation into masonry enclosures. For
noncombustible applications, the barbecue drops into the opening shown in Figures 3 and Fig. 4, (below). A ledge
is required to support the barbecue from the bottom. Models CGBD36 and CGBD48 also require a ledge in the
center of the opening to support the middle of the unit. The supporting ledges must be level and flat. The counter
top should also be level.

It is recommended that ventilation holes are provided in the enclosure in the event of a gas leak. The installer-
supplied gas shut-off valve must be installed in an easily accessible location.

CharGlo

®

Outdoor Barbecues

Model No.

Overall Dimensions

Cutout Dimensions

A

B

C

D

E

F

CGBD30RX

24-

3

/

4

30-

7

/

16

26-

5

/

8

11-

15

/

16

29-

3

/

4

22-

3

/

4

CGBD36RX

24-

3

/

4

36

26-

5

/

8

11-

15

/

16

35-

5

/

16

22-

3

/

4

CGBD48RSBX

24-

3

/

4

48

26-

5

/

8

11-

15

/

16

47-

5

/

16

22-

3

/

4

CGBD48RX

24-

3

/

4

48

26-

5

/

8

11-

15

/

16

47-

5

/

16

22-

3

/

4

Figure 3

Figure 4

C

E

F

B

A

3" minimum for
hood clearance
to back wall

Cutout Dimensions for

30", 36" and 48" Built-in Units

D

F

E

OPENING FOR
ACCESS DOOR

GAS
INLET

3" MINIMUM FOR
LID CLEARANCE

36"

12"

NON-COMBUSTIBLE
ENCLOSURE

12"

12"

Properly Grounded
3-Prong Receptacle

36

Center Support
Ledge for
CGBD36 and CGBD48