Connecting procedures, Wr-da7 setup, Midi timepiece a/v setup – Teac WR-DA7 User Manual

Page 53

Advertising
background image

54

3.15 Connection to MAX (Macintosh) expansion software and

Other Sequence Software

This example illustrates a recording and mixing automation system using one WR-DA7, PC expan-
sion software, and sequencing software such as Digital Performer. The combined use of the
expansion software and Digital Performer makes it possible to control the WR-DA7 and MIDI
devices in synchronization with MIDI timecode.

Connecting Procedures

Connect the printer port of the Macintosh computer to the [To PC] port of the WR-DA7 and the
modem port of the Macintosh computer to the Mac port of MIDI Timepiece A/V using Macintosh
serial cross cables (printer cables). Remember that the MIDI Timepiece A/V computer button
must be up in the Mac position (not pressed).

To send timecode to the Macintosh computer with the DA-98 serving as timecode master, connect
MIDI OUT of the DA-98 to Port 4 IN of MIDI Timepiece A/V and Port 3 OUT of MIDI Timepiece
A/V to MIDI IN of the WR-DA7 using standard MIDI cables.

For MMC control of the DA-98 from the WR-DA7, connect the MIDI OUT of the WR-DA7 to the
MIDI IN of the DA-98 using a MIDI cable.

This system uses the DA-98 as the wordclock master and synchronizes the WR-DA7 with the WR-
TDIF card, therefore no word clock connection is necessary.

For communication from the MIDI sequencer to the MIDI sampler and MIDI keyboard, connect
the MIDI Timepiece A/V to each MIDI device using a MIDI cable.

WR-DA7 Setup

This system uses the DA-98 as word clock master. The WR-DA7 is synchronized with the DA-98
that is connected to Slot 1. So, set [Source Select] to [Slot 1] on the D-I/O input set screen.

To receive MTC from the DA-98 and make the expansion software through, set [MTC Port] to
[MIDI] and [Thru] in the item [Others] to [ON]. As MMC is transmitted from the WR-DA7 to the
DA-98, set [MMC Port] to [MIDI] and match [MIDI CH] with the MIDI/bus ID of the DA-98.

MIDI Timepiece A/V Setup

To send the MTC received from the DA-98 to the WR-DA7, establish a connection from Port 4 IN to
Port 3 OUT.

To send the MTC received from the DA-98 to the Macintosh (for the MIDI sequencer), establish a
connection from Port 4 IN to the computer.

To connect the Macintosh computer (for the MIDI sequencer) to the MIDI devices, establish con-
nections from Port 1 and Port 2 IN and OUT to the computer.

Advertising