Optional rack-mounting equipment, Mounting, Rack mounting – Transition Networks SM24-100SFP-AH User Manual

Page 30: Mounting 3-2, Figure 3-1, Attaching the brackets

Advertising
background image

3-2

Installing the Switch

3

Optional Rack-Mounting Equipment

If you plan to rack-mount the switch, be sure to have the following equipment
available:

• Four mounting screws for each device you plan to install in a rack—these are not

included

• A screwdriver (Phillips or flathead, depending on the type of screws used)

Mounting

The switch units can be mounted in a standard 19-inch equipment rack or on a
desktop or shelf. Mounting instructions for each type of site follow.

Rack Mounting

Before rack mounting the switch, pay particular attention to the following factors:

Temperature: Since the temperature within a rack assembly may be higher than

the ambient room temperature, check that the rack-environment temperature is
within the specified operating temperature range. (See page D-2.)

Mechanical Loading: Do not place any equipment on top of a rack-mounted unit.

Circuit Overloading: Be sure that the supply circuit to the rack assembly is not

overloaded.

Grounding: Rack-mounted equipment should be properly grounded. Particular

attention should be given to supply connections other than direct connections to
the mains.

To rack-mount devices:

1.

Attach the brackets to the device using the screws provided in the Bracket
Mounting Kit.

Figure 3-1. Attaching the Brackets