Connectivity rules, 1000base-t cable requirements, 1000 mbps gigabit ethernet collision domain – Transition Networks SM24-100SFP-AH User Manual

Page 38: Table 4-1, Maximum 1000base-t gigabit ethernet cable length, Table 4-2, Maximum 1000base-sx gigabit ethernet cable length, Table 4-3, Maximum 1000base-lx gigabit ethernet cable length

Advertising
background image

4-4

Making Network Connections

4

The maximum length for fiber optic cable operating at Fast Ethernet speed will
depend on the fiber type as listed under “100 Mbps Fast Ethernet Collision Domain”
on page 4-5
. The maximum length for fiber optic cable operating at Gigabit speed
will depend on the fiber type as listed under “1000 Mbps Gigabit Ethernet Collision
Domain” on page 4-4.

Connectivity Rules

When adding hubs (repeaters) to your network, please follow the connectivity rules
listed in the manuals for these products. However, note that because switches break
up the path for connected devices into separate collision domains, you should not
include the switch or connected cabling in your calculations for cascade length
involving other devices.

1000BASE-T Cable Requirements

All Category 5 UTP cables that are used for 100BASE-TX connections should also
work for 1000BASE-T, providing that all four wire pairs are connected. However, it is
recommended that for all critical connections, or any new cable installations,
Category 5e (enhanced Category 5) or Category 6 cable should be used. The
Category 5e specification includes test parameters that are only recommendations
for Category 5. Therefore, the first step in preparing existing Category 5 cabling for
running 1000BASE-T is a simple test of the cable installation to be sure that it
complies with the IEEE 802.3-2005 standards.

1000 Mbps Gigabit Ethernet Collision Domain

Table 4-1. Maximum 1000BASE-T Gigabit Ethernet Cable Length

Cable Type

Maximum Cable Length

Connector

Category 5, 5e, 6 100-ohm UTP or STP

100 m (328 ft)

RJ-45

Table 4-2. Maximum 1000BASE-SX Gigabit Ethernet Cable Length

Fiber Size

Fiber Bandwidth

Maximum Cable Length

Connector

62.5/125 micron

multimode fiber

160 MHz/km

2-220 m (7-722 ft)

LC

200 MHz/km

2-275 m (7-902 ft)

LC

50/125 micron multimode

fiber

400 MHz/km

2-500 m (7-1641 ft)

LC

500 MHz/km

2-550 m (7-1805 ft)

LC

Table 4-3. Maximum 1000BASE-LX Gigabit Ethernet Cable Length

Fiber Size

Fiber Bandwidth

Maximum Cable Length

Connector

9/125 micron

single-mode fiber

N/A

2 m - 5 km (7 ft - 3.2 miles) LC