Appendix A: Troubleshooting

Diagnosing Switch Indicators

Diagnosing Power Problems with the LEDs

The Pwr and BPS LEDs work in combination to indicate power status as follows.

Table A-1. Troubleshooting Chart

Symptom

Action

Pwr LED is Off

• Power supply is disconnected.
• Check connections between the switch, the power cord, and the wall

outlet.

• Contact your dealer for assistance.

Pwr LED is Amber

• Internal power supply has failed. Contact your local dealer for assistance.

OK LED is Amber

• Power cycle the switch to try and clear the condition.
• If the condition does not clear, contact your dealer for assistance.

Port 1-28 LED is Off

• Verify that the switch and attached device are powered on.
• Be sure the cable is plugged into both the switch and corresponding

device.

• Verify that the proper cable type is used and its length does not exceed

specified limits.

• Check the adapter on the attached device and cable connections for

possible defects. Replace the defective adapter or cable if necessary.

Table A-2. Pwr/BPS LEDs

Pwr LED

BPS LED

Status

Green

Yellow

Internal power functioning normally; BPS plugged in

but faulty, such as a thermal or fan failure.

Green

Off

Internal power functioning normally; BPS not

plugged in.

Yellow

Green

Internal power faulty; BPS delivering power.

Off

Off

Both internal power and BPS unplugged or not

functioning.