Basic vf-s11 operations – Toshiba VF-S11 User Manual

Page 28

Advertising
background image

E6581160

27

4

4. Basic VF-S11 operations

The VF-S11 has the following four monitor modes.

Standard monitor mode

: The standard inverter mode. This mode is enabled when

inverter power goes on.

This mode is for monitoring the output frequency and setting the frequency
designated value. In it is also displayed information about status alarms during
running and trips.

• Setting frequency designated values ⇒ see 3.1.2
• Status alarm

If there is an error in the inverter, the alarm signal and the frequency will flash
alternately in the LED display.

E

:

When a current flows at or higher than the overcurrent stall level.

R

:

When a voltage is generated at or higher than the over voltage stall
level.

N

:

When a load reaches 50% or higher of the overload trip value.

J

:

When the temperature reaches the overheating protection alarm level.

Setting monitor mode

: The mode for setting inverter parameters.

How to set parameters

⇒ see 4.2

Status monitor mode

: The mode for monitoring all inverter status.

Allows monitoring of set frequencies, output current/voltage and terminal
information.

For more on how to use the monitor

⇒ see 5.1

Pressing the key

will move the inverter through each of the modes.

Standard monitor

mode

Status monitor

mode

Setting monitor

mode

MODE

MODE

MODE

Panel jog mode

: This mode allows you to jog the motor by controlling the

operation from the operation panel.

This mode is hidden by default.

To use the panel jog mode, set the parameter H to.

MODE

Advertising