Qtable of input terminal functions 3, Qtable of output terminal functions 1 – Toshiba VF-S11 User Manual

Page 68

Advertising
background image

E6581160

67

7

Q

Table of input terminal functions 3

Function

No.

Code

Function

Action

54

STN

Coast stop (gate off)

ON: Coast stop (gate off)

55

RESN

Inversion of RES

ON: Acceptance of reset command
OFF

→ ON: Trip reset

56

F+ST

Combination of forward run and standby

ON: Simultaneous input from F and ST

57

R+ST

Combination of reverse run and standby

ON: Simultaneous input from R and ST

58

AD3

Acceleration/deceleration 3 selection

ON: Acceleration/deceleration 3
OFF: Acceleration/deceleration 1 or 2

59

F+AD3

Combination of forward run and
acceleration/deceleration 3

ON: Simultaneous input from F and AD3

60

R+AD3

Combination of reverse run and
acceleration/deceleration 3

ON: Simultaneous input from R and AD3

61

OCS2

Forced switching of stall prevention level 2

ON: Enabled at the value of H
OFF: Enabled at the value of H

62

HDRY

Holding of RY-RC terminal output

ON: Once turned on, RY-RC are held on.
OFF: The status of RY-RC changes in real time

according to conditions.

63

HDOUT

Holding of OUT-NO terminal output

ON: Once turned on, OUT-NO are held on.
OFF: The status of OUT-NO changes in real time

according to conditions.

64

PRUN

Cancellation (clearing) of operation command from
panel

0: Operation command canceled (cleared)
1: Operation command retained

65

ICLR

PID control integral value clear

ON: PID control integral value always zero
OFF: PID control permitted

Q

Table of output terminal functions 1

Function

No.

Code

Function

Action

0

LL

Frequency lower limit

ON: The output frequency is above the NN set

value.

OFF: The output frequency is equal to or less than

the NN set value.

1

LLN

Inversion of frequency lower limit

Inversion of LL setting

2

UL

Frequency upper limit

ON: Output frequency is equal to or higher than

WN

value.

OFF: Output frequency is lower than WN value.

3

ULN

Inversion of frequency upper limit

Inversion of UL setting

4

LOW

Low-speed detection signal

ON: Output frequency is equal to or higher than

H

value.

OFF: Output frequency is lower than H

value.

5

LOWN

Inversion of low-speed detection signal

Inversion of LOW setting

6

RCH

Designated frequency attainment signal
(completion of acceleration/deceleration)

ON: The output frequency is equal to or less than

the specified frequency ± frequency set with
H

.

OFF: The output frequency is above the specified

frequency ± frequency set with H.

7

RCHN

Inversion of designated frequency attainment
signal (inversion of completion of
acceleration/deceleration)

Inversion of RCH setting

8

RCHF

Set frequency attainment signal

ON: The output frequency is equal to or less than

the frequency set with H ± H.

OFF: The output frequency is above the frequency

set with H ± H.

9

RCHFN

Inversion of set frequency attainment signal

Inversion of RCHF setting

10

FL

Failure signal (trip output)

ON: When inverter is tripped
OFF: When inverter is not tripped

11

FLN

Inversion of failure signal (inversion of trip output)

Inversion of FL setting

Advertising