Attention – Tradewins Furniture RNC5-TPD User Manual

Page 12

Advertising
background image

Ventilation Dehumidistat

PART NO. 99-116

The High/Low Speed Switch initiates High or Low speed
ventilation. This control also has an ON/OFF Switch and a
Dehumidistat Dial (refer to "The ON/OFF Switch" and "The
Dehumidistat Dial" descriptions).

Recirculation Control

PART NO. 99-RECIRC Note: For use with RNC5-TPD only

The Recirculation Switch will toggle from continuous low
speed ventilation to recirculation mode (closes the fresh air
damper and circulates the building air). The Dehumidistat
Dial will initiate High Speed ventilation when the indoor
humidity level exceeds the set point (regardless position of
the RECIRC Switch.). This control also has an ON/OFF
Switch and a Dehumidistat Dial (refer to "The ON/OFF
Switch" and "The Dehumidistat Dial" descriptions).

Remote Control Devices

20 Minute Timer

PART NO. 99-132

Connects to RED, BLACK and GREEN
(LED drive) terminals. Use a minimum of
three 20 gauge low voltage wire. Connect
up to 4 on 100 ft (91 m) wire max. Mounts in
a 2 x 4 box.

DEHUMIDIST

AT

Off

10

20

30

40

50

60

Optional Main Controls

The amount of ventilation required in your home will fluctu-
ate according to the activity level in the house. Higher activity
levels require more ventilation.

Main controls can be mounted in a central location of the
home (i.e. beside the furnace thermostat) which will provide
the user with complete control over their ventilation system
from a convenient location.

The ON/OFF Switch

The ON/OFF Switch will turn the HRV ON or OFF. Controls
with an ON/OFF switch can be modified to ON/Standby by
adjusting the circuit board DIP Switches (Refer to "Mode DIP
Switch Settings").

The Dehumidstat Dial

Main controls feature a dehumidistat dial. The dehumidistat
is used to reduce high winter humidity levels. The dehumidis-
tat activates high speed ventilation when the indoor humidity
level exceeds selected setting.

Optional Timers

Timers should be present when the HRV is exhausting from
specific locations i.e bathrooms, laundry rooms. The 20

Minute Timer is the best selection, however, the crank timer
will be necessary if only 2 lead low voltage wires are pres-
ent.

Only one main control can be installed on your
system.

ATTENTION

Dehumidistat
Dial

High/Low
Speed Switch

ON/OFF
Switch

Crank Dial
Rotate the dial for up to 60
minutes high speed opera-
tion.

D e h u m i d i s t a t
Dial

Recirculation
Switch

ON/OFF
Switch

20/40 ON/OFF Dehumidistat

PART NO. 99-2040

The 20/40 Switch will toggle from continuous low speed ven-
tilation to an intermittent mode of 20 minutes fan ON (in low
speed) and 40 minutes fan OFF. The Dehumidistat Dial will
initiate High Speed ventilation when the indoor humidity level
exceeds the set point (regardless position of the 20/40
Switch.). This control also has an ON/OFF Switch (refer to
"The ON/OFF Switch" description).

Remote Dehumidistat

PART NO. 99-130 White

The Remote Dehumidistat activates high speed ventilation
when the indoor humidty level exceeds the set point.

Dehumidistat
Dial

20/40

Switch

ON/OFF
Switch

Dehumidistat
Dial

Crank Timer

PART NO. 99-101

Connects to RED and BLACK termi-
nals. Use a two 18 gauge low
voltage wire. Mounts in a 2 x 4 box.
The crank timer provides a solution
to installing a system where only 2
wires are present for the timers.

20 Minute Status Lights
The 20 Minute Status Light indicates
high speed operation is activated.

Touch Pad
The Touch Pad initi-
ates

high

speed

operation.

12