Engineering Data

Model RNC5-TPD

THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE

The cross-flow heat recovery core transfers heat between the two airstreams.
It is easily removed for cleaning or service.

MOTORS AND BLOWERS

Each Air stream has an independent motorized impeller. 120VAC

FILTERS

Washable air filters in exhaust and supply air streams.

DEFROST

The damper closes off the supply air from outside allowing the exhaust air to
recirculate through the unit.

CASE

Twenty gauge prepainted galvanized steel (G60) for superior corrosion resist-
ance. Insulated to prevent exterior condensation. Drain connections 1/2" (12
mm) OD.

MOUNTING THE HRV

Four threaded inserts at corners of case designed to accept four reinforced
polyester straps that are supplied with the unit.

CONTROLS- HRV System Control

HRV defaults to user selected speed from switch on top of cabinet when
plugged in. HIGH SPEED option is accessible by connecting remote controls
to designated terminals inside electrical box of HRV.

OFF(Standby)/LOW or OFF/HIGH speed operation is also available.

DUCT CONNECTIONS

4 - 5” (127 mm) duct connections.

Weight 61 lbs. (28 kg) Shipping Weight 64 lbs. (29 kg)

All units conform to CSA and UL standards.

27”

(690 mm)

15”

(378 mm)

2-1/4”

(57 mm)

18-3/4”

(475 mm)

SPEED
SELECTION
SWITCH

TM

HEAT RECOVERY VENTILATOR

HEAT RECOVERY VENTILATOR

Dimensions

OPTIONAL ACCESSORIES

99-101 Crank Timer

99-116 Dehumidistat Ventilation Control - Dehumidistat with ON/OFF

99-130 Dehumidistat Control - Dehumidistat

99-132 20 Minute Fan Timer - (3 wire) 20 gauge wire (min.) 100’ length

(max.)

99-185 Weatherhoods, Two - 5” (125mm) c/w 1/4” (6mm) mesh screen

99-186 Weatherhoods, Two - 6" (150mm) c/w 1/4" (6mm) mesh screen

99-2040 20/40 ON/OFF Dehumidistat

99-RECIRC Recirculation Control

WARRANTY

Units carry a fifteen (15) year warranty on the heat recovery core and a 5
year replacement parts warranty.

1

2

3

0

20

40

60

80

100

120

140

160

180

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1

1.1

Static Pressure (in w.g.)

A

ir

F

lo

w

(c

fm

)

3 - High Speed
*2 - Medium Low Speed
*1 - Low speed

* Manufacturers Data

*Sensible Efficiency - thermal **Latent Efficiency - moisture

Note: Effectiveness - based on temp. differential between the 2 airstreams
Efficiency - takes into account all power inputs

Performance

(H.V.I. certified)

Net supply air flow in cfm (L/s) against external static pressure

E.S.P

(external static pressure)

[cfm (L/s)]

@ 0.1" (25 Pa)

169 (80)

@ 0.2" (50 Pa)

156 (73)

@ 0.3" (75 Pa)

149 (70)

@ 0.4" (100 Pa)

136 (64)

@ 0.5" (125 Pa)

126 (59)

@ 0.6" (150 Pa)

116 (54)

@ 0.7" (175 Pa)

103 (48)

@ 0.8" (200 Pa)

89 (42)

@ 0.9" (225 Pa)

77 (36)

@ 1.0" (250 Pa)

58 (27)

Max. Temperature Recovery

78%

Sensible Effectiveness
@ 66 cfm (31 L/s)

32°F (0°C)

74%

*Sensible Efficiency
@ 66 cfm (31 L/s)

32°F (0°C)

61%

*Sensible Efficiency
@ 76 cfm (36 L/s)

-13°F (-25°C)

63%

VAC @ 60HZ

120

WATTS / Low speed.

69

WATTS / High speed

147

Amp rating

1.7