3 precautions in transportation – Toshiba GF632 User Manual

Page 22

Advertising
background image


- 21 -

6F8A0883

4.2.3 Precautions in transportation

To prevent the device from being damaged during transportation, the original packing should be left
untouched until the device arrives near the intended installation site.
The detector is equipped with hanging hooks. Lift it as shown in Figure 4.5. For information on the
actual mass of each diameter, refer to Table 4.2.














* The lifting work should be executed by those qualified for crane work or slinging work




















Figure 4.6 Transportation of GF63* flowmeter detector

CAUTION

(1)Never lift the detector by inserting a bar

into its measurement pipe, because this will
damage the linings, thus making it impossible
to take stable measurements.



(2)To put the flowmeter temporarily on the floor,

place it carefully with something, such as
stopper, to support it so that GF630/LF600F,
GF630/LF610F and GF632 will not topple over
.

Wire or cloth belt

is used.

Cloth belts should only can be used

because wire may cause damage to

the detector or converter body.

(a) Meter size 200mm to 600mm (8" to 24")

Hanging hooks are provided

(b) Meter size 15mm to 150mm (1/2" to 6")

Hanging hooks are not provided

Stopper, etc. to prevent from toppling over it.

flowmeter

90°

or less

Lifting Lugs

flowmeter

A bar, etc. to lift
the flowmeter.

Advertising
This manual is related to the following products: