Handling precautions (continued), About disposal – Toshiba GF632 User Manual

Page 8

Advertising
background image


- 7 -

6F8A0883

Handling Precautions (continued)

(6) If the inside of the converter and detector's terminal box are wetted or humidified, it may

cause insulation deterioration, which can result in fault or noise occurrence. So do not
conduct wiring in the open air on rainy days.
Also, be careful not to wet down the converter and detector's terminal box even in the
case of indoor wiring, and complete wiring work in a short period of time.

(7) Make sure the fluid to be measured will not freeze in the detector pipe. This can cause

damage to the detector pipe.

(8) Select appropriate wetted materials suited for the process fluid to be measured. Otherwise,

fluid leakage due to corrosion can be caused.

(9) Observe the following precautions when you open the converter housing cover:

Do not open the cover in the open air unprotected against rain or wind. This can
cause electric

shock

or

cause

damage

to

the

flowmeter electronics.

Do not open the cover under high ambient temperature or high humidity
conditions or in corrosive atmospheres
. This can cause deterioration of system accuracy
or cause damage to the flowmeter electronics.

(10) Since a varistor is built in converter, do not conduct a withstand voltage test for

the converter.
In addition, the voltage for checking the insulation of the converter must be 250VDC
or lower.

(11) This product may cause interference to radio and television sets if they are used

near the installation site. Use metal conduits etc. for cables to prevent this
interference
.

(12) Radio transmitters such as transceivers or cellular phones may cause interference to

the flowmeter if they are used near the installation site. Observe the following
precautions when using them:

Close a transmitter cover before using a transceiver.

Do not use a transceiver whose output power is more than 5 W.

Move the antenna of a transceiver or a cellular phone at least 50 cm away from the
flowmeter and signal cables when using it.

Do not use a radio transmitter or a cellular phone near the flowmeter while it is
operating online. The transmitter or cellular phone’s output impulse noise may interfere
with the flowmeter.

Do not install a radio transmitter antenna near the flowmeter and signal cables.

(13) For reasons of flowmeter failure, inappropriate parameters, unsuitable cable

connections or poor installation conditions, the flowmeter may not operate properly. To
prevent any of these problems causing a system failure, it is recommended that you
have preventive measures designed and installed on the flowmeter signal receiving
side
.

(14) For installation and connectirn of the converter, check the model number of

converter and read the instruction manual of the relevant converter.

* We assume no responsibility for nonconformity caused by violation of precautions described in this

manual or used in violation of the installation method and the operation method stipulated in a
relevant ordinance or other regulations.

About disposal

When you dispose of this electromagnetic flowmeter detector, follow the ordinance or regulations of your
state.

Advertising
This manual is related to the following products: