Toshiba STRATA CIX User Manual

Page 81

Advertising
background image

Telephone Button Programming

500 Series Programs

Strata CIX/CTX Telephone Button Programming 11/04

1-77

T

e

le

phon

e Butt

on

Pr
og
ramm

ing

507-01

DDCB Equipment No.

FB01

, xxyyzz,

Hold

xx =

Cabinet 01 (CTX100),
01~02 (CTX670 Basic),
01~07 (CTX670 Exp.)

Enter the DDCB equipment number to which the Door phone should
be assigned.

Example: If the DDCB interface should be connected to a PDKU or
BDKU/BDKS in cabinet shelf 5, slot 2, circuit 3, enter 050203.

Notes

This is the cabinet, slot, and circuit number of the BDKU/BDKS or
PDKU interface PCB to which the DDCB is to be connected.

If a PDN is assigned to the DDCB equipment number it must be
deleted, using Program 201, before attempting to assign the
DDCB console.

Cabinet numbers:

CTX100 ñ Select 01 for Base and Expansion cabinet.

CTX670 ñ Select 01 for Base and 02~07 respectively for each
Expansion cabinet.

Slot numbers:

CTX100 ñ Select 01~04 for Base slots and 05~08 for Expansion
slots.

CTX670 ñ Select 01~08 for Base slots and 01~10 for Expansion
slots.

yy =

Slot 01~8 (CTX100),
01~10 (CTX670)

zz =

Circuit 01~16

507-02

Tenant Number

FB02

, n,

Hold

n =

1~2 (CTX100)
1~8 (CTX670) (default = 1)

Select the Tenant Number for which the door phone should ring over
external page in the system Night mode.

507-03

Connection Status

n =

1.

Enable

2.

Disable

(default)

Check the box if the door phone is physically connected to the DDCB.

507-04

Ring Duration

FB04

, n,

Hold

n =

3~30
(default = 9)

Select the time that the door phone should ring destination devices
when the door phone button is pressed. The ring time can be 3 to 30
seconds set in 3 second intervals - each 3 second interval provides
one ring to the destination. Destination devices include selected DNs
and Page groups.

507-05

LCD Name Display

FB05

, n,

Hold

n =

1~16

Enter the Door Phone name that should display on LCD telephones
when the door phone rings the telephones; or, when the telephone
calls the door phone.

507-06

Day1 Destination

FB06

, n,

Spkr

, n1,

Hold

n =

1.

None

(default)

2.

DN

3.

Paging Group
1~4 (CTX100)
1~8 (CTX670 Basic)
1~16 (CTX670 Exp.)

1.

Select Destination Type ñ Select the type of destination that
should ring when the door phone button is pressed during the
system Day1, Day2 or Night mode.

2.

Enter the Destination Number ñ If the ring destination type is a
PDN or PhDN, enter the directory number. If the ring destination
type is Page, enter the Page Group number.

n1 =

Up to 5 digits

507-07

Day2 Destination

FB07

, n,

Spkr

, n1,

Hold

n =

1.

None

(default)

2.

DN

3.

Paging Group
1~4 (CTX100)
1~8 (CTX670 Basic)
1~16 (CTX670 Exp.)

1.

Select Destination Type ñ Select the type of destination that
should ring when the door phone button is pressed during the
system Day1, Day2 or Night mode.

2.

Enter the Destination Number ñ If the ring destination type is a
PDN or PhDN, enter the directory number. If the ring destination
type is Page, enter the Page Group number.

n1 =

Up to 5 digits

507-08

Night Destination

FB08

, n,

Spkr

, n1,

Hold

,

Hold

n =

1.

None

(default)

2.

DN

3.

Paging Group
1~4 (CTX100)
1~8 (CTX670 Basic)
1~16 (CTX670 Exp.)

1.

Select Destination Type ñ Select the type of destination that
should ring when the door phone button is pressed during the
system Day1, Day2 or Night mode.

2.

Enter the Destination Number ñ If the ring destination type is a
PDN or PhDN, enter the directory number. If the ring destination
type is Page, enter the Page Group number.

n1 =

Up to 5 digits

Table 1-35

Programs 500~577

(continued)

Button

Sequence

Value(s)

Summary

Advertising