When h is not  , and h is  (disabled), When h is not  , and h is not, Example of setting 1 – Toshiba Tosvert VF-AS1 User Manual

Page 181: Example of setting 2

Advertising
background image

E6581301

F-69

6

An example of setting: When HJ is , and H is 

800

0

1000

0

Panel indication

800

0

Panel indication

Panel indication

H=, H=

H=, H=

H=, H=

0

80(Hz)

0

80(Hz)

Output frequency

Output frequency

Output frequency 80 (Hz)

H

H

H

200

0

6.36.3 Changing the steps in which the value displayed changes

H

: Changing step selection 1 (pressing a panel key once)

H

: Change step selection 2 (panel display)

Function

These parameters are used to specify steps in which the command value or standard monitor output
frequency displayed on the panel changes each time you press the up or down key to set a frequency on
the operation panel.

Note: The settings of these parameters have no effect when the free unit selection (H) is enabled.

When H is not , and H is  (disabled).

Under normal conditions, the panel frequency command value increases in steps of 0.1Hz each time you press the

key. If H is not 0.00, the frequency command value will increase by the value with H each time you

press the

key. Similarly, it will decrease by the value set with H each time you press the

key.

In this case, the output frequency displayed in standard monitor mode changes in steps of 0.1Hz, as usual.

When H is not , and H is not .

The value displayed on the panel also can be changed in steps.

Output frequency displayed in standard monitor = Internally output frequency ×

H
H

Title

Function

Adjustment range

Default setting

H

Changing step selection 1
(pressing a panel key once)



.:Disabled



.~HJ Hz



.

H

Changing step selection 2
(panel display)



:Disabled



~



Example of setting 1

Set H=[Hz]:

Each time you press the

key, Each time the frequency setting HE changes in steps of 10.0Hz: 0.0

→ 10.0 →

20.0

→ ... → 60.0 [Hz]. This function comes in very handy when operating the load at limited frequencies that

change in steps of 1 Hz, 5Hz, 10Hz, and so on.

Example of setting 2

Set H=[Hz], H=:

Each time you press the

key, the frequency setting HE changes in steps of 1 Hz: 0

→ 1 → 2 → ... → 60 [Hz]

and also the value displayed on the operation panel changes in steps of 1. Use these settings to hide decimal
fractions. And also the value displayed on the operation panel changes in steps of 1. Use these settings to hide
decimal fractions.