TANDBERG 880 MXP User Manual

Page 305

Advertising
background image

Appendices

291

Cable Specification
RS-530/RS-366
TANDBERG MXP and Classic Endpoints that support External
Network


• Connector on Tandberg End:

o

Female 26pin High Density DSUB Newark P/N 50F2055 or Equivalent

• Connector on RS-530:

o

DSUB 25 pin Male

• Connector on RS-366:

o

DSUB 25 pin Male

• Cable

length:

o

1

meter

Signal Name

Female

26pin

DSUB

(Tandberg

end)

Pin

Number

Male

25pin

DSUB

RS-530

(DCE end)

Pin

Number

Male

25pin

DSUB

RS-366

Pin

Number

Comments

Frame Ground

1

1

Do not connect shield to FGND

Signal Ground

19

7

Send Data (A)
Send Data (B)

11
12

2

14

Twisted Pair

Send Timing (A)
Send Timing (B)

17
18

15
12

Twisted Pair

Receive Data (A)
Receive Data (B)

13
14

3

16

Twisted Pair

Receive Timing(A)
Receive Timing (B)

15
16

17

9

Twisted Pair

Terminal Ready(A)
Terminal Ready(B)

20
21

20
23

Receiver Ready (A)

22

8

Twisted Pair

Receiver Ready (B)

23

10

Twisted Pair

LOS A

25

18

LOS A Unbalanced

RS366 DPR

2

2

RS366 ACR

3

3

RS366 CRQ

4

4

RS366 PND

5

5

RS366 DLO

6

22

RS366 NB1

7

14

RS366 NB2

8

15

RS366 NB4

9

16

RS366 NB8

10

17

RS366 GND

1

7



Advertising
This manual is related to the following products: