LEVELING

A. For proper performance of refrigerated cabinet an

ambient temperature no greater than 75˚F (24˚C)

with a relative humidity of 55% is required.

B. Proper leveling of your TRUE deli case is critical to

operating success. Effective condensate removal and

door operation will be effected by leveling.

C. The deli case should be leveled front to back and

side to side with a level (see figure 1). Place the level

in the interior floor of the unit in the four positions

illustrated. (See figure 2).

D. If the cabinet is not level adjust leg levelers by first

relieving weight to leveler and adjusting by either

hand or wrench. Repeat with all leg levelers until

cabinet is level in all directions.

E. Ensure that the drain hose or hoses are positioned in

the condensate pan. (See Figure 1).

F. Free plug and cord from inside the lower rear louver

of the cooler (do not plug in). (See figure 1).

G. The deli case should be placed close enough to the

electrical supply so that extension cords are never

used.

WARNING

Cabinet warranties are void if OEM power cord is tampered

with. TRUE will not warranty any units that are connected to

an extension cord.

A. Remove packing material behind cabinet as a

cushion. Carefully lay the unit on its back to remove

skid.

When lifting unit remember to leave the

cabinet upright for 24 hours before

plugging into power source.

B. Remove skid by unscrewing all base rail anchor

brackets. Place skid to the side.

C. Carefully lift cabinet upright.
D. Applicance tested according to the climate classes 5

and 7 for temperature and relative humidity.

LOCATING

Removing skid from

bottom of cabinet.

Condensate pan
drain hoses

Figure 1

Plug and cord

REMOTE UNITS (This section applies to remotes only!)

• Remote cabinets must be ordered as remote. We do

not recommend converting from a standard self

contained to remote system.

• All remote cabinets must be hard wired.
• No castors available.
• All remote cabinets come standard using 404A

refrigerant.

• All remote units come standard with expansion

valve, liquid line solenoid, heated condensate pan,

and defrost timer when applicable.

• Contact TRUE Technical Service for BTU requirements.
• No wiring necessary between cabinet and

condensing unit.

• All remote condensing units purchased from TRUE are

208/230 volts single phase.

Cabinet warranties are void if OEM power cord is tampered

with. TRUE will not warranty any units that are connected to

an extension cord.