DEFROST TIME CLOCK OPERATION

(GRASSLIN TIMER)

RECOMMENDED DEFROST SETTINGS:
TRUE Manufacturing has factory set your

defrost time clock to a recommended time

and duration defrost scenario. All units

will require routine defrosts. Your TRUE

equipment has been designed for three

defrost periods (6:00 a.m., 2:00 p.m. and

10:00 p.m.). If you decide to deviate from

these defrost time settings please follow the

procedures for adjustment below.

NOTE
Defrost timer will need to be set at current

time of day before plugging unit into power

supply.

REQUIRED TOOLS:
• Phillips Screwdriver
• 1/4" Nut Driver or Socket

Locating The Defrost Timer:
Defrost timer is located in the lower right

corner behind the louvered grill (inside

galvanized electrical box).

Take off louvered grill assembly by

removing four (4) corner screws.

Setting the timer:
(UNPLUG UNIT FROM
POWER SUPPLY!)

DO NOT SET THE TIME BY ROTATING THE

“OUTER” DIAL.
Turn the minute hand clockwise until the

time of day on the outer dial is aligned with

the triangle marker on the inner dial (two

o’clock position).

Adjusting The Defrost Timer:
(time initiated, time or temperature

terminated)

Your TRUE equipment contains a defrost

system that is temperature terminated,

however the time clock has been designed

with a time termination back-up so that

the defrost period will not exceed thirty

minutes. While TRUE requires a minimum

3 defrost periods not to exceed 60 minutes

the procedure on this page should be

followed to customize your specific needs.

NOTICE
If timer is not set for a minimum of 3

defrost per day for 60 minutes each, the coil

may develop excessive frost. This may lead

to system failure and product loss, which is

not covered under warranty.

The following procedure may be followed

to customize your needs.

High usage, high temperature, and high

humidity may require 4 defrost settings

per day.

WARNING
Always follow the manufacturer’s

recommended settings when programming

the amount and duration of the defrost cycles.

STEP 1
The white tabs located on the outmost area

of the time clock have been factory set for

(6:00 a.m., 2:00 p.m., and 10:00 p.m.).

Each tab represents 15 minutes of defrost

time. Notice that at each defrost time four

white tabs are set for 15 minutes each for a

total of 60 minutes of defrost.

STEP 2
In order to program the time to begin the

defrost cycle, flip the white tabs out to set

the defrost time. To eliminate a defrost time

flip the white tabs back toward the center of

the Defrost Timer.

STEP 3
TRUE recommends a 60 minute defrost

cycle three times per day.

Outer most dial. White tabs

represent 15 minutes of

defrost time.

Time of day.

Inner most dial.

Defrost Timer Image 2