Roam Option

The following key sequence is used to enter the roam option:

Press:

#

*

6

*

<home only>

*

<SOC disable> #

When the home only value is set to 0, the Phonecell will use the SOC/SID list specified in the IRDB
along with the home SID and home SOC when searching for service, and will search for the highest
priority service provider that is not forbidden. When the home only value is set to 1, the Phonecell
will use only the home SID and home SOC. If the home only value is not set to 0 or 1, it is consid-
ered invalid. The factory default is 0.

SOC disable defines whether the SID or SOC takes priority when classifying a service provider.
When the SOC disable value is set to 0, the highest priority classification of either the SID or SOC
will take precedence; when set to 1, the SID priority will take precedence. If the SOC disable value
is not in the range 0 or 1, it is considered invalid. The factory default is 0.

Band Order (System) Selection

The following key sequence is used to enter the preferred band order:

Press:

#

*

7

*

<band order> #

The band order value is a series of digits between 1 and 2 (1 and 8 for Tri-Mode model) that must
be at least 1digit and not more than 2 digits (8 digits for Tri-Mode model) long. The following table
describes the relationship between the band order digits and EIA/TIA-136 system/band assignment:

Band Order Digits

EIA/TIA-136

1

System A (800 MHz)

2

System B (800 MHz)

3

Band A (1900 MHz)

4

Band B (1900 MHz)

5

Band C (1900 MHz)

6

Band D (1900 MHz)

7

Band E (1900 MHz)

8

Band F (1900 MHZ)

The factory default is 12 for the TDMA 800 model and 34125678 for the Tri-Mode model.

Post Receiver Off-Hook Option

The following key sequence is used to enter the post receiver off-hook option:

Press:

#

*

9

*

<post ROH option> #

The post ROH value is set to 0 for continuous ROH tone; 1 to disable ROH tone and periodically
check for an on-hook condition. If the post ROH value is neither 0 nor 1, it is considered invalid. The
factory default is 1.

System Operator Code

The following key sequence is used to program the system operator code:

Press:

#

*

77

*

<code> #

If the code value is not in the range of 0 to 4,095, it is considered invalid. The factory default is 0.

Emergency Numbers

The following key sequence is used to program the emergency numbers:

Press:

#

*

78

*

<index> <emergency number> #

The index is a number from 1 to 3 representing the emergency number to be programmed. If the
emergency number is less than 3 digits or more than 10 digits, it is considered invalid and the FWT
will not update or store this value; the currently stored value will remain. The factory default is an
emergency number of 911 in index 1; indices 2 and 3 are not programmed.