FREEZERS DEFROST TIME CLOCK

OPERATION (Grasslin Timer)

RECOMMENDED DEFROST SETTINGS:
TRUE Manufacturing has factory set your

defrost time clock to a recommended

time and duration defrost scenario. All

refrigeration equipment operating below 30°F

will accumulate frost on the evaporator coil

and will require routine defrost. Your TRUE

equipment has been designed for three

defrost periods (6:00 a.m., 2:00 p.m. and

10:00 p.m.). If you decide to deviate from

these defrost time settings please follow the

procedures for adjustment below.

REQUIRED TOOLS:
• Phillips Screwdriver
• 1/4” Nut Driver or Socket

Locating The Defrost Timer:
Take off the timer box lid by removing four

(4) corner screws.

Single Door Models:
Defrost timer is located in top of the cabinet

in the timer box connected to the evaporator

housing.

Two Door Models:
Defrost timer is located in top of the cabinet

in timer box connected to the evaporator

housing.

Three Door Models:
Defrost timer is located on top and right-

hand side of the cabinet. The timer is in

the timer box connected to the side of the

condenser housing.

Setting the timer:

(UNPLUG UNIT FROM

POWER SUPPLY!)

DO NOT SET THE TIME BY

ROTATING THE “OUTER” DIAL.

Turn the minute hand clockwise until the

time of day on the outer dial is aligned with

the triangle marker on the inner dial (two

o’clock position).

Adjusting The Defrost Timer:

(time initiated, time or temperature

terminated)

Your TRUE freezer contains a defrost system

that is temperature terminated, however the

time clock has been designed with a time

termination back-up so that the defrost

period will not exceed thirty minutes. While

TRUE requires a minimum 3 defrost periods

not to exceed 30 minutes the procedure on

this page should be followed to customize

your specific needs.

NOTICE:
If timer is not set for a minimum of 3 defrost

per day for 30 minutes each, the coil may

develop excessive frost. This may lead to

system failure and product loss, which is not

covered under warranty.

The following procedure may be followed to

customize your needs.

High usage, high temperature, and high

humidity may require 4 defrost settings per

day.

WARNING:

Always follow the manufacturer’s

recommended settings when programming the

amount and duration of the defrost cycles.

STEP 1
The white tabs located on the outmost area

of the time clock have been factory set for

(6:00 a.m., 2:00 p.m., and 10:00 p.m.). Each

tab represents 15 minutes of defrost time.

Notice that at each defrost time two white

tabs are set for 15 minutes each for a total of

30 minutes of defrost.

STEP 2
In order to program the time to begin the

defrost cycle, flip the white tabs out to set the

defrost time. To eliminate a defrost time flip

the white tabs back toward the center of the

Defrost Timer.

STEP 3
TRUE recommends a 30 minute defrost

cycle three times per day.

Inner most dial.

Time of day.

Outer most dial. White tabs represent 15
minutes of defrost time.

Defrost Timer Box Image 1