True Manufacturing Company TR1RRI-1S User Manual

Page 21

Advertising
background image

............ www.truemfg.com ............

True Food Service Equipment, Inc.

19

19

• Disconnect power to unit.
• Three door units will need the rainshield removed to

easily access the condenser coil for cleaning. Back out the

top screws (see image 2) and the bottom screws (see image

3) anchoring the rainshield. Unplug the wires connected

to the rear of the digital temperature thermometer (see

image 3) and set the rainshield to the side.

NOTE (For Three Door Units Only)
Remember to mark which wire plugs into the rear of the digital

temperature thermometer for easy assembly of the rainshield.

• Clean off accumulated dirt from the condenser coil

and the fan with a stiff bristle brush. After brushing the

components off vacuum all dirt residue from the coil, fan,

and surrounding areas.

NOTE
Single door freezer models are supplied with a long handle

stiff bristle brush. This brush is used to reach through tight

clearances when cleaning the condenser coil (see image 1).

MAINTENANCE, CARE & CLEANING

CLEANING THE CONDENSER COIL

When using electrical appliances, basic safety precautions should be followed, including the following:

Single Door Freezer unit
(Brush Provided)

Three Door Freezer unit
(Rainshield Removal/top
screws)

Three Door Freezer unit
(Rainshield Removal / bottom
screws)

Digital Temperature Control Connections.
(Rainshield Removal)

1

2

3

4

MAINTENANCE, CARE & CLEANING

Advertising