Program module (pgm-7) – TP-Link RX-7-248 User Manual

Page 14

Advertising
background image

Each program module incorporates two program output channels (programs A and B) and
each program channel can be controlled independently.

1. PROGRAM OUTPUT B connector (XLR type) is balanced, transformer-isolated. The

nominal level and impedance are +4dB and 600 ohms, respectively. The program output B
signal is derived from one of the four group out busses.

2. GROUND (GND) LIFT switch is for pin 1, which is used to avoid ground loops that are

often caused in connection with other equipment and that may induce hum. Sliding the
ground lift switch from the NORMAL position to the LIFT position cuts ground loops and

may reduce hum. For most applications it should be set to the NORMAL position.

3. PROGRAM OUTPUT A connector (XLR type) is balanced, transformer-isolated. The

nominal level and impedance are +4dB and 600 ohms, respectively. The program output

A signal is derived from one of the four group out busses.

4. GROUND (GND) LIFT switch is for pin 1, which is used to avoid ground loops that are

often caused in connection with other equipment and that may induce hum. Sliding the
ground lift switch from the NORMAL position to the LIFT position cuts ground loops and

may reduce hum. For most applications it should be set to the NORMAL position.

PROGRAM OUT "A" SECTION

5. GROUP 1, 2, 3 and 4 controls pick up the signal from the four Group out busses, and

assign them to this program output channel.

6. PROGRAM MASTER control adjusts the overall mixed signal level of any four Group

signals assigned to this channel.

7. PROGRAM ON/OFF pushbutton connects or disconnects the program signal to the

program output connector. The green LED illuminates when the program out is "on".

8. PEAK level indicator turns on when the program output signal level reaches l0dB above

nominal.

9. PHONES selector switches assign the program signal of this channel to the phones

module. The switches allow for the selection of L (left) and/or R (right) of the phones

output. If the program output is required for monitoring via headphones, the program

monitoring button on the phones module must be ON.

PROGRAM OUT "B" SECTION

Functions on program out B section are the same as the Program out A.

10. GROUP 1, 2, 3 and 4 controls

11. PROGRAM MASTER control

12. PROGRAM ON/OFF pushbutton

13. PEAK level indicator

14. PHONES selector switches

Program Module (PGM-7)

(Fig. 7)

— 13 —

Advertising