Hints for test centres, Technical specifications – Tricity Bendix DH 086 User Manual

Page 16

Advertising
background image

16

Hints for test centres

Before starting any test it is necessary to fill completely with salt the salt container and with rinse aid the rinse aid
dispenser.

Test standard

EN 50242

Reference programme:

POWER WASH 65°C

Load:

8 standard place settings

Rinse aid selector:

position 4

Detergent dosage :

20 g in the dispenser

5 g on the dispenser lid

US62

UI57

Arrangement
upper basket

Arrangement

lower basket

DIMENSIONS

Width

45 cm

Height with worktop

85 cm

Height without worktop

82 cm

Max depth

60 cm

Max depth with open door

115.9 cm

ELECTRICAL CONNECTION

Voltage

220/240 V - 50 Hz

POWER OF HEATING ELEMENT

2570 W

OVERALL POWER

2770 W

WATER SUPPLY PRESSURE

Minimum

50 kPa (0.5 bar)

Maximum

800 kPa (8 bar)

CAPACITY

8 place settings

Technical specifications