Electrical connection – Tricity Bendix DH 086 User Manual

Page 18

Advertising
background image

18

Electrical connection

This appliance must be earthed.
The manufacturer declines any responsibility
should this safety measure not be observed.

If the plug that is fitted to your appliance is not suitable for
the socket, it must be cut off and the appropriate plug fitted.

Important
The wires on the mains lead are coloured in accordance
with the following code:

Green and Yellow-Earth
Blue

-Neutral

Brown

-Live

If you fit your own plug, the colours of the wires in the mains
lead of your appliance may not correspond with the
markings identifying the terminals in your plug.

Proceed as follows:

1. Connect the Green and Yellow (earth) wire to the

terminal in the plug which is marked with the letter "E" or
the earth symbol

or coloured green and yellow.

2. Connect the Blue (neutral) wire to the terminal in the plug

which is marked with the letter "N" or coloured black.

3. Connect the Brown (live) wire to the terminal in the plug

which is marked with the letter "L" or coloured red.

The plug moulded onto the lead incorporates a 13amp
BSI362 fuse. Only ASTA or BSI fuses should be used.

The plug must not be used if the fuse cover/carrier is lost.
The cover/carrier is indicated by the coloured insert at the
base of the product.

A replacement cover/carrier must be obtained from your
local Service Force Centre.

This appliance complies with the following E.E.C.
Directives:

- 73/23 or 19.2.73 (Low Voltage Directive) and
subsequent modifications;

- 89/336 or 3.5.89 (Electromagnetic Compatibility
Directive) and subsequent modifications.

CE03

Advertising