FIGURE 15C - Typical Wiring Diagram for Model UDAP or Model UDAS, Two Stage Gas Valve

VENTER

FAN MOTOR

PRESSURE SWITCH

SPARK GAP

OPERATING SEQUENCE

1. SET THERMOSTAT AT LOWEST SETTING, (FAN SWITCH AT "AUTO" POSITION, OPTION CL18 ONLY).

2. TURN ON MANUAL GAS VALVE.

3. TURN ON POWER TO UNIT.

4. SET THERMOSTAT AT DESIRED SETTING.

5. LOW STAGE OF THERMOSTAT CALLS FOR HEAT, ENERGIZING THE VENTER MOTOR.

6. VENTER PRESSURE SWITCH CLOSES, FIRING UNIT AT LOW RATE.

7. BURNER FLAME IS SENSED, AND IN 30 SECONDS THE FAN MOTOR IS ENERGIZED.

10. IF THE FLAME IS EXTINGUISHED DURING MAIN BURNER OPERATION,

THE INTEGRATED CONTROL SYSTEM CLOSES THE MAIN VALVE AND

MUST BE RESET BY INTERRUPTING POWER TO THE CONTROL CIRCUIT

(SEE LIGHTING INSTRUCTIONS).

GREEN LED

NOTES

1. THE FOLLOWING CONTROLS ARE FIELD INSTALLED OPTIONS: THERMOSTAT

2. DOTTED WIRING INSTALLED BY OTHERS.

3. CAUTION: IF ANY OF THE ORIGINAL WIRING AS SUPPLIED WITH THE

APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL

HAVING A TEMPERATURE RATING OF AT LEAST 105° C. EXCEPT FOR SENSOR

LEAD WIRE, FLAME ROLLOUT AND LIMIT WIRING WHICH MUST BE 150° C.

4. USE 18 GA. WIRE FOR ALL WIRING ON THE UNIT.

5. LINE AND FAN MOTOR BRANCH WIRE SIZES SHOULD BE OF A SIZE TO PREVENT

VOLTAGE DROPS BEYOND 5% OF SUPPLY LINE VOLTAGE.

FIELD CONTROL WIRING

150'
250'
350'

75'
125'
175'

#18 GA. WIRE
#16 GA. WIRE
#14 GA. WIRE

TOTAL WIRE

LENGTH

DISTANCE FROM
UNIT TO CONTROL

MIN. RECOMMENDED

WIRE GUAGE

LED

Y

Y

WIRE NUT

FIELD WIRING
OPTIONAL FACTORY

FACTORY WIRING

DSI CONTROL

SW1

FAN OFF DELAY

TIME

90

120
160
180

OFF

OFF

ON
ON

ON

OFF
OFF

ON

1

2

S W

FAST FLASH
1 FLASH
2 FLASH

3 FLASH
4 FLASH

STEADY OFF

LED FLASH CODES

NORMAL OPERATION CALL FOR HEAT
IN LOCKOUT FROM FAILED IGNITIONS OR FLAME
PRESSURE SWITCH DOES NOT CLOSE WITHIN

LIMIT SWITCH OR ROLLOUT SWITCH OPEN
PRESSURE SWITCH IS CLOSED BEFORE

VENTER IS ENERGIZED

INTERNAL CONTROL FAULT OR NO POWER

YELLOW LED

FLAME SENSED

STEADY ON
SLOW FLASH WEAK FLAME

UNDESIRED FLAME (VALVE OPEN & NO CALL

FOR HEAT)

FAST FLASH

IND BK

NEUTRAL

W

MOTOR

LED

OK

FLAME

G

Y

NEUTRAL

BK

W

LIMIT CONTROL

R

R

R

R

FLAME ROLLOUT

R

BR

FLAME

ELECTRODE

FLAME

GROUND

P1-8

P1-3

P1-6

P1-5

P1-7

P1-9

BK

W

24V

115/208/230

Y

BK

BR

R

L1

NEUTRAL NEUTRAL

L1

COM

SEC

SYSTEM TRANSFORMER

EAC/BLO

W

WIRING

30 SECONDS OF VENTER ENERGIZED

VO

LT

BK

AT

O OR A

TC

3.0 AMP

C

R

W

G

Y

RH

W1

R

W1

TERMINAL STRIP

Y

PR

P3-4

P3-3

P3-2

TEST

NORMAL OPERATION NO CALL FOR HEAT

STEADY ON

G

G

G

G

G

GRD

SCREW

LINE/1/60

30 VA

CAPACITOR

(SEE NOTE #6)

CAPACITOR

(SEE NOTE #7)

BR/W

BR

BR

BR/W

SPARK

TRANSFORMER

G

(MODELS 30-125 ONLY)

P3-5

P3-1

G

WIRING CODE

BLACK - BK

BROWN - BR

RED - R

ORANGE - O

YELLOW - Y

GREEN - G

BLUE - BL

PURPLE - PR

WHITE - W

6. CAPACITOR IS REMOTE MOUNTED AND INCLUDED ONLY ON 115V MODELS

150-400 AND 208/230V MODELS 100-400.

7. CAPACITOR IS REMOTE MOUNTED AND INCLUDED ONLY ON MODELS 150 - 400.

Y

8. SET THERMOSTAT FIRST STAGE ANTICIPATOR AT 0.6 AMPS AND

SECOND STAGE ANTICIPATOR AT 0.2 AMPS.

W2

W2

Q674C SUBBASE (SEE NO

TE #8 AND #9)

(OPT CL18)

T874F

THERMOST

AT

O

P1-4

P1-2

W

STG

HIGH

HI

GAS VALVE

HONEYWELL

TWO STAGE

LO

W

C

LO

STG

BR

BL

O

W2

W1

(OPT CL7)

T874F

THERMOST

AT

Q674G SUBBASE (SEE NO

TE #8)

R

9. SET FAN SWITCH AT "ON" POSITION FOR CONTINUOUS FAN OPERATION, OPTION CL18 ONLY.

8. HIGH STAGE OF THERMOSTAT CALLS FOR HEAT, FIRING UNIT AT FULL RATE.

FUSE

RC

9. JUMPER THERMOSTAT TERMINALS RH TO RC.

LO

W

TWO STAGE

GAS VALVE

HIGH

STG

HI

MV

C

STG

HONEYWELL

ALT.

DOOR INTERLOCK

(UDAS ONLY)

R

R

DISCONNECT SWITCH

(UD

AS ONL

Y)

BK

BK

BL

BR

O

WD# 185244 REV #3 AG2