Adjustments

Technical Manual LDK 20(S) - Studio Camera

4-3

Test Equipment

The following is a list of equipment required to carry out
the adjustment procedure:

Set of board extenders LDK 4830/21

Oscilloscope (with cursor measurement)

Spotlight 3200K

Gamma Test chart 4:3 / 16:9

Waveform monitor

Colour monitor

Multimeter

Master Control Panel LDK 4607 / LDK 4609

Operational Control Panel LDK 4624 / LDK 4628 /
LDK 4629

Audio Analyser

Base Station LDK 4053

Set-up Instructions

Before carrying out any adjustments the following steps
are recommended:

Install the camera on a tripod.

Attach the lens and the necessary cables.

Allow the camera to warm-up.

Operate the camera in stand-alone mode

Connect an MCP and OCP to the data connector on
the right connector panel of the camera.

When the camera is used in the stand-alone mode,
MCP and OCP always operate in camera select
position 1 (OCP camera select switch in position 1).

CAUTION:

Do not attempt to improve camera performance

by adjusting individual potentiometers, jumpers or switches

as this may lead to complete misalignment of the camera.

CAUTION:

Do not realign individual potentiometers, jumpers or switches

not mentioned in this chapter or earlier in this manual.

These adjustment points are for factory use only.

CAUTION:

Switch off the power supply to the camera

before removing or replacing printed circuit boards.