Auto iris
1. Point camera at and fill frame with a white 90% reflecting test chart, illuminated with a 3200K spotlight. Set

iris to F5.6.

Measure at:

Adjust with:

Required result:

CVBS out

Waveform monitor

100% video level.

2. On OCP, ensure that the IRIS CENTRE control is turned fully counterclockwise and the IRIS RANGE control

is turned fully clockwise. Move iris control first fully up and then fully down. Then set iris control to its mid-
position.

3. On OCP, switch AUTO IRIS to AUTO.
4. Observe waveform monitor and adjust auto iris level on camera control panel for 70% white with setpoint

potentiometer.

Measure at:

Adjust with:

Required result:

CVBS out

Setpoint

70% white

pos. = 42

(490mV)

5. On OCP, set COLOUR TEMP. switch to position AW1.
6. Press AW button once so that the AW window is visible in the viewfinder and on the PXM monitor.
7. Press the AW button a second time to start the automatic white process.
8. During the automatic white process observe the waveform monitor. The mom. iris should be 70% white.

Measure at:

Adjust with:

Required result:

CVBS out

70% white

(490mV)

9. Point camera at gamma test chart illuminated with a 3200K spotlight.
10. Observe waveform monitor and with the peak/average value set to 50 on the camera control panel, adjust

the peak/average potentiometer on the miscellaneous board for 90% white.

Measure at:

Adjust with:

Required result:

CVBS out

ZR187

90% white

(630mV)