Defrost timer instructions – True Manufacturing Company TWT-60F User Manual

Page 10

Advertising
background image

............ www.truemfg.com ............

True Food Service Equipment, Inc.

INSTALLATION / OPERATION INSTRUCTIONS

8

8

Defrost Time Clock Operation

Instructions for TUC-60-32F, 67F,

93F, TWT-60-32F,

67F, and 93F models.

RECOMMENDED DEFROST SETTINGS:

TRUE Manufacturing has factory set your

defrost time clock to a recommended time

and duration defrost scenario. Your TRUE

equipment has been designed for three

defrost periods (6:00 a.m., 2:00 p.m. and

10:00 p.m.). If you decide to deviate from

these defrost time settings please follow the
procedures for adjustment below.

NOTE

Defrost timer will need to be set at

current time of day before plugging

unit into power supply. The defrost

times have been set from the factory.

If you want to change defrost times

please read through the defrost timer

instructions.

REQUIRED TOOLS:
• Phillips Screwdriver

• 1/4” Nut Driver or Socket

TUC/TWT Defrost Timer Location:

Defrost timer can be found by removing the

rear screen.

Setting the timer:

(UNPLUG UNIT FROM

POWER SUPPLY!)

Turn the clock (outer dial) clock-wise until

the correct time of day on the outer dial is

aligned with the marker of the inner dial.
(See image 2).

Adjusting The Defrost Timer:

(time initiated, time terminated)

Your TRUE equipment contains a defrost

system that is time initiated and time

terminated. While TRUE requires a

minimum 3 defrost periods not to exceed 30

minutes the procedure on this page should be
followed to customize your specific needs.

NOTICE

If timer is not set for a minimum of 3 defrost

per day for 30 minutes each, the coil may

develop excessive frost. This may lead to

system failure and product loss, which is not

covered under warranty.

The following procedure may be

followed to customize your needs.

High usage, high temperature, and

high humidity may require 4 defrost

settings per day.

WARNING

Always follow the manufacturer’s

recommended settings when

programming the amount and duration

of the defrost cycles.

Defrost Timer Image 2

STEP 1

The white tabs located on the outmost area

of the time clock have been factory set for

(6:00 a.m., 2:00 p.m., and 10:00 p.m.). Each

tab represents 15 minutes of defrost time.

Notice that at each defrost time two white

tabs are set for 15 minutes each for a total of
30 minutes of defrost.

STEP 2

In order to program the time to begin the

defrost cycle, flip the white tabs out to set the

defrost time. To eliminate a defrost time flip

the white tabs back toward the center of the
Defrost Timer.

STEP 3

TRUE recommends a 30 minute defrost

cycle three times per day.

Defrost Timer Box Image 1

Outer most dial. White tabs represent 15 minutes
of defrost time.

Time of day.

Inner most dial.

DEFROST TIMER INSTRUCTIONS

Advertising
This manual is related to the following products: