4

SPeCIfICATION AND INSTALLATION

Proper placement of the oven will enhance
long-term operator convenience and satisfactory
performance. Be sure to place the oven in an area
accessible for proper operation and servicing.

The surface on which the oven is placed must be at
least 30” (762 mm) deep and capable of supporting
200 lb. (90.7 kg) for the HhC 2020 and 265 lb. (118
kg) for the HhC 2620 (weights are per oven). The
manufacturer shall not assume liability for damage
or injury resulting from the improper installation of
this equipment including temporary or unstable work
stations or countertops.

The oven must be installed level front to back and side
to side. For additional stability, the oven legs may be
bolted to the countertop if desired.

Installation Near Open Heat Source

Figure 11.

When placing a TurboChef oven near an open heat
source, strictly adhere to the following:
- If the oven is being placed near a grill or stove,

a divider must exist between the oven and the

open heat source, with a minimum of 6” (152

mm) between the oven and the divider.

- If the oven is being placed near a fryer, a divider

must exist between the oven and fryer, with a

minimum of 12” (305 mm) between the oven

and the divider.

- The height of the divider must be greater than

or equal to the height of the oven(s) - 13” (330

mm) without legs or 17” (432 mm) with legs.

- Verify oven location has a minimum 10”

(254 mm) clearance on top and minimum

2” (51 mm) of clearance on each side.

Ventilation requirements

The HhC 2020/HhC 2620 should be operated
underneath a ventilation hood, except where local
laws or codes allow for use without a ventilation
hood, unless the oven is a UL-certified ventless model
(available upon request). For more information or to
order a ventilation hood, contact 800.90turbo, +1
214-379-6000, or your local distributor.
The TurboChef HhC 2020/HhC 2620 oven has been

approved by Underwriter’s Laboratory for ventless

operation (UL 710B, KNLZ listing) for all food items

except for foods classified as “fatty raw proteins.”

Such foods include bone-in, skin-on chicken, raw

hamburger meat, raw bacon, raw sausage, steaks, etc.

If cooking these types of foods, consult local HVAC

codes and authorities to ensure compliance with

ventilation requirements.

The HhC 2020 is approved for ventless operation

while double or triple stacked. The HhC 2620 is

approved for ventless operation while double stacked.

NOTE: In no event shall the manufacturer assume

any liability for damages or injuries resulting from

installations which are not in compliance with the

instructions and codes previously listed.

Grill

Partition

Above Counter Top:

Single Oven = 17.0” (432 mm)

Double Stack = 30.0” (762 mm)

Triple Stack = 43.0” (1092 mm)

6”

(152 mm)

Minimum

12”

(305 mm)

Minimum

Deep Fryer

Counter Top / Table

Partition

Above Counter Top:

Single Oven = 17.0” (432 mm)

Double Stack = 30.0” (762 mm)

Triple Stack = 43.0” (1092 mm)

figure 11: Installation Near Open Heat Source