TurboChef Technologies TurboChef High h Conveyor 2020 User Manual

Page 21

Advertising
background image

13

STANDA

rD

O

Ve

N

O

Per

ATION

Adjusting the Belt Speed

The oven can accommodate either one or two con-
veyor belts. The oven will automatically detect the
number of conveyor belts installed and display the
option to change the speed of each conveyor belt
independently.

1. From Figure 14, press the soft key adjacent

to the conveyor belt you wish to adjust

(press L2 for the front belt [Belt F] or L3

for the rear belt [Belt R]).

2. Adjust the time it takes for the conveyor

belt to completely cycle through the oven.

- The up key increases bake time in

5-second increments up to 20 minutes.

+ Flex option enabled: the user can only

increase the time up to an additional

15

seconds.

- The down key decreases bake time in

5-second increments.

+ Flex option enabled: the user cannot

decrease the time by more than 15

seconds.

3. Press the soft key adjacent to the belt that

was adjusted to exit the belt speed controls.

Adjusting the Temperature

1. Press R2 (Figure 14, page 12) to access the

temperature controls.

2. Adjust the temperature (range is 300-550°F
[149-288°C]).

- Press the up key to increase the

temperature in 5°F/5°C increments.

+ Flex option enabled: the user can only

increase the temperature up to an

additional

10°F/5°C.

- Press the down key to decrease the

temperature in 5°F/°5C increments.

+ Flex option enabled: the user cannot

decrease the temperature by more than

10°F/5°C.

3. Press R2 again to exit temperature controls.

Adjusting the Top and Bottom Air

1. Press R1 (Figure 14, page 12) to access the

top air controls, or R3 to access the bottom

air controls.

2. Adjust the air speed.

- Press the up key to increase the air speed in 5%

increments up to 100%.

+Flex option enabled: the user can only

increase the air speed by up to an

additional 15%.

- Press the down key to decrease the air

speed in 5% increments down to 30%.

+Flex option enabled: the user cannot

decrease the air speed by more than

15%.

- Press the soft key again to exit the air

controls.

Advertising