TP-Link TL-SF2226P User Manual

Page 21

Advertising
background image

TL-SF2226P+/TL-SL2226P+

Remote Smart Switch User Guide

10HD: 10Mbps, Half-Duplex.

10FD: 10Mbps, Full-Duplex.

100HD: 100Mbps, Half-Duplex.

100FD: 100Mbps, Full-Duplex

2) Flow Control:

Disable: The port won't produce Flow Control packets and will discard the Flow
Control packets received.

Enable: The Switch will negotiate Flow Control on the specified port according to
Full-Duplex or Half-Duplex.

3) Port Security: When you configure the Port Security of a port to be Enable, the

port won't learn any new MAC address. Furthermore, the port only transfers the
data accordant to static MAC Address. If the port does not bind any static MAC
address, the port will not transfer data. When the Port Security of a port is
disabled, the port will automatically learn any new MAC Address and transfer
data.

Default setting: Disable

4) Default PVID: There is the choice only in the IEEE802.1Q Tag VLAN mode.

Every port on the Switch has a default VID which is the VID for an untag Tag
received by the port.

5) Default Value: 1

6) User Info: User Info just gives the port a description.

4. Priority Config

Steps of Configuring Priority:

Click main menu->Config->Priority Config or click the priority icon on toolbar. As figure
5-17.

- 18 -

Advertising
This manual is related to the following products: