Tnetx4090 thunderswitch ii, Switch, Terminal functions (continued) dio interface – Texas Instruments THUNDERSWITCH II TNETX4090 User Manual

Page 16: Eeprom interface

Advertising
background image

TNETX4090
ThunderSWITCH II

9-PORT 100-/1000-MBIT/S ETHERNET

SWITCH

SPWS044E – DECEMBER 1997 – REVISED AUGUST 1999

16

POST OFFICE BOX 655303

DALLAS, TEXAS 75265

Terminal Functions (Continued)

DIO interface

TERMINAL

I/O

INTERNAL

DESCRIPTION

NAME

NO.

I/O

RESISTOR

DESCRIPTION

SAD0
SAD1

AF22
AE22

I

Pullup

DIO address bus. Selects the internal host registers provided SDMA is high. Internal pullup
resistors are provided.

SCS

AD22

I

Pullup

DIO chip select. When low, SCS indicates a DIO port access is valid. An internal pullup resistor
is provided.

SDATA0
SDATA1
SDATA2
SDATA3
SDATA4
SDATA5
SDATA6
SDATA7

AF20
AE20

AD20
AC20

AF21
AE21

AD21
AC21

I/O

Pullup

DIO data bus. Byte-wide bidirectional DIO port. External pullup resistors are required.

SDMA

AF24

I

Pullup

DIO DMA select. When low, SDMA modifies the behavior of the DIO interface to allow it to
operate efficiently with an external direct memory access (DMA) controller. SAD0 and SAD1 are
not used to select the internal host register for the access. Instead, the DIO address to access
internal registers is provided by the DMAAddress register, and one of two host register
addresses is selected according to dmainc in SysControl. An internal pullup resistor is provided.

SINT

AF19

O

None

Interrupt. Interrupt to the attached microprocessor. The interrupt type can be found in the Int
register.

SRDY

AF23

O

Pullup

DIO ready. When low during reads, SRDY indicates to the host when data is valid to be read.
When low during writes, SRDY indicates when data has been received. SRDY is driven high
for one clock cycle before placing the output in high impedance after SCS is taken high. An
internal pullup resistor is provided.

SRNW

AC22

I

Pullup

DIO read not write

– When high, read operation is selected.
– When low, write operation is selected.

An internal pullup resistor is provided.

SRXRDY

AE23

O

None

Network management (NM) port, receive ready. When high, SRXRDY indicates that the NM
port’s receive buffers are completely empty and the NM port is able to receive a frame of any
size up to 1535 bytes in length.

STXRDY

AD23

O

None

Network management (NM) port, transmit ready. When high, STXRDY indicates that at least
one buffer of frame data is available to be read by the management CPU. It outputs a 1 if any
of the end-of-frame (eof), start-of-frame (sof), or interior-of-frame (iof) bits in NMTxControl is set
to 1, otherwise, it outputs 0.

EEPROM interface

TERMINAL

I/O

INTERNAL

DESCRIPTION

NAME

NO.

I/O

RESISTOR

DESCRIPTION

ECLK

L26

O

None

EEPROM data clock. An internal pullup resistor is provided.

EDIO

M26

I/O

Pullup

EEPROM data input/output. An internal pullup resistor is provided.

Advertising