Tnetx4090 thunderswitch ii, Switch, Terminal functions jtag interface – Texas Instruments THUNDERSWITCH II TNETX4090 User Manual

Page 7: Control logic interface

Advertising
background image

TNETX4090

ThunderSWITCH II

9-PORT 100-/1000-MBIT/S ETHERNET

SWITCH

SPWS044E – DECEMBER 1997 – REVISED AUGUST 1999

7

POST OFFICE BOX 655303

DALLAS, TEXAS 75265

Terminal Functions

JTAG interface

TERMINAL

I/O

INTERNAL

DESCRIPTION

NAME

NO.

I/O

RESISTOR†

DESCRIPTION

TCLK

L24

I

Pullup

Test clock. Clocks state information and test data into and out of the TNETX4090 during operation
of the test port.

TDI

M24

I

Pullup

Test data input. Serially shifts test data and test instructions into the TNETX4090 during operation
of the test port. An internal pullup resistor is provided on TDI to ensure JTAG compliance.

TDO

L23

O

None

Test data out. Serially shifts test data and test instructions out of the TNETX4090 during operation
of the test port.

TMS

M25

I

Pullup

Test mode select. Controls the state of the test-port controller. An internal pullup resistor is provided
on TMS to ensure JTAG compliance.

TRST

L25

I

Pullup

Test reset. Asynchronously resets the test-port controller. An internal pullup resistor is provided on
TRST to ensure JTAG compliance.

† Internal resistors are provided to pull signals to known values. The system designers should determine if additional pullups or pulldowns are

required in their systems.

control logic interface

TERMINAL

I/O

DESCRIPTION

NAME

NO.

I/O

DESCRIPTION

RESET

M23

I

Device reset. Asserted for a minimum of 100

µ

s after power supplies and clocks have stabilized. The system clock

must be operational during reset.

FLOW

AF8

O

Flow control. When flow control is activated (flow in SysControl = 1) and the number of free external memory
buffers is below the threshold indicated in FlowThreshold, FLOW is asserted.

100-/1000-Mbit/s MAC interface [gigabit media-independent interface (GMII) (port 8)]

TERMINAL

NAME

I/O

INTERNAL

RESISTOR†

DESCRIPTION

M08_PMA

I

Pullup

PMA mode. PMA mode can be selected by either pulling M08_PMA low externally, or by setting the
reqpma bit in the PortxControl register. If M08_PMA is allowed to float high, the port is configured as
either an MII or GMII interface, as determined by the value of the M08_MII terminal.

M08_MII

I

Pullup

MII or GMII selection. The value of this terminal is ignored if M08_PMA = 0. 100-Mbit/s MII mode can
be selected by either pulling M08_MII low externally, or by setting the req100 bit in the PortxControl
register. If M08_MII is allowed to float high, the port is configured as a GMII interface.

† Internal resistors are provided to pull signals to known values. The system designers should determine if additional pullups or pulldowns are

required in their systems.