Tnetx4090 thunderswitch ii, Switch – Texas Instruments THUNDERSWITCH II TNETX4090 User Manual

Page 43

Advertising
background image

TNETX4090

ThunderSWITCH II

9-PORT 100-/1000-MBIT/S ETHERNET

SWITCH

SPWS044E – DECEMBER 1997 – REVISED AUGUST 1999

43

POST OFFICE BOX 655303

DALLAS, TEXAS 75265

EEPROM interface (continued)

After the initial start condition, a slave address containing a device address of 000 is output on EDIO, and then
EDIO is observed for an acknowledge from the EEPROM. If an acknowledge is received, operation continues
for the 24C02 EEPROM. If none is received, a stop condition is generated, followed by another start condition
and slave address, this time containing a device address of 101. If this receives no acknowledge, no EEPROM
is present, and device operation continues, using the current register settings (i.e., those following a hardware
reset, or those previously entered by software).

When this device is driving EDIO, it drives out only a strong logical 0. When a logical 1 is intended to be driven
out, the terminal must be resistively pulled high. An on-chip 50-

µ

A current-source pullup device is provided on

this terminal. The system designer must decide if this is sufficient to achieve a logical 1 level in a timely manner
or if an external supplementary resistor is required.

Multiple bus masters are not supported on the EEPROM interface because the ECLK terminal always is driven
by the device with a strong 0/strong 1 (i.e., not a strong 1/resistively pulled-up 1).

An Ethernet CRC check is used to ensure the EEPROM data is valid. The 4-byte CRC should be placed within
the EEPROM in four data bytes immediately following the last byte to be loaded (equivalent to locations
0x00FC–0x00FF, just above SysControl). As each byte is loaded from the EEPROM, the bits within that byte
are entered into the CRC checker bit-wise, most significant bit first.

A valid CRC always must be provided by the EEPROM. The EEPROM data for the most significant bit of
SysControl is withheld until the CRC computed by the device has been checked against the one read from the
EEPROM. If the CRC is invalid:

D

The reset bit is set to 1 in SysControl, load and initd are both 0, and the TNETX4090 does not begin
operation.

D

The fault LED is illuminated and remains in that state until the TNETX4090 is hardware reset or until load
in SysControl is set to 1.

interaction of EEPROM load with the SIO register

The EDIO terminal is shared with the SIO register edata bit. The edata and etxen bits must not both be set to
1 when the load bit is set or the EDIO terminal is held at resistive 1 and the EEPROM load fails.

The value of the eclk bit in SIO is don’t care when load is set, but to ensure the EEPROM does not see a glitch
on its clock signal, the load bit should not be set until the minimum clock high or low time required by the
EEPROM on its clock signal has expired since the eclk bit was last changed.

The SIO register is not loaded during the EEPROM download.

summary of EEPROM load outcomes

Table 14 summarizes the various states of register bits and the fault LED for each possible outcome following
an EEPROM load attempt.

Table 14. Summary of EEPROM Load Outcomes

OUTCOME

STOP

LOAD

INITD†

FAULT LED

ECLK

Successful load

0

0

1

0‡

Not locked

No EEPROM present

0

0

0

0‡

Locked

CRC error detected

1

0

0

1

Not locked

† Assuming the start bit was set to 1 by the EEPROM load
‡ Assuming the fault bit in LEDControl = 0 and no memory system parity error is detected