English 3

For island installations, the hood width should, at a
minimum, overhang the range by 3" on each side.

Important:

Ventilation hoods and blowers are designed for use with
single wall ducting. However, some local building codes or
inspectors may require double wall ducting. Consult local
building codes and/or local agencies, before starting, to
assure that hood and duct installation will meet local
requirements.

Do not install a microwave oven/ventilator combination
above the range, as these type of units do not provide the
proper ventilation and are not suitable for use with the
range.

2.

Hood Placement:

For best smoke elimination, the lower edge of the hood
should be installed 30" above the range cooking
surface. (See Figure 1).

NOTICE:

Most range hoods contain combustible components which
must be considered when planning the installation.

If the hood contains any combustible materials (i.e. a
wood covering), it must be installed a minimum of 40"
above the cooking surface.

3.

Consider Make-Up Air:

Due to the high volume of ventilation air, a source of
outside replacement air is recommended. This is
particularly important for tightly sealed and insulated
homes.

A qualified heating and ventilating contractor should be
consulted.

Range

Width

Range Top Configuration

Ventilation Options

30"

4 burners

30" or 36" Pro Wall Hood

30" or 36” Custom Insert w/ optional blower

42" Island Hood w/ optional blower

36"

4 burners with griddle

36" or 42" Pro Wall Hood

36" Custom Insert w/ optional blower

42" or 48" Island Hood w/ optional blower

6 burners

48"

6 burners with griddle

48" or 54" Pro Wall Hood **

48" Custom Insert w/ optional blower

Important Notes:

• It is recommended that a Thermador Professional wall or island hood or custom insert is used with Thermador

Professional Ranges.

• The HPWB or PH Professional Series Wall Hoods or the Professional Series Custom Inserts are recommended

ventilation solutions for these ranges.

• Refer to www.Thermador.com for a complete selection of Professional Ventilation options, Blowers, and

Accessories.

• For high output gas ranges (60,000 BTU or greater), the minimum of one (1) CFM of ventilation per 100 BTU is

recommended. If the range has a griddle, add 200 CFM to the estimated blower capacity. Additional blower capacity
may be required for longer duct runs.

• For island applications, it is recommended to use a hood width that exceeds the width of the range by 6" (overlapping

the range by a minimum of 3" on each end).

• ** Not all 48” Pro Wall Hood models can accommodate a 1,300 CFM blower option.

• CFM = “cubic feet per minute” (standard blower capacity rating).