Figure 1: cabinet clearances, Figure 1 – Thermador PRL36 User Manual

Page 7

Advertising
background image

Figure 1: Cabinet Clearances

For Electrical and Gas Supply Zone, see
Figure 3A.

Cooking

Surface

,

CAUTION:

See Figure 2
36" Min. to
combustible

material

Ð

,

from cooking

surface

as defined in the “National Fuel Gas Code” (ANSI Z223.1,

Current Edition).*The range height is adjustable. The level
of the range top must be at the same level or above the
countertop level.

Range width

30", 36" or 48"

30" or 36" Wide Hood
36" or 42" for Island

}

For 30" Ranges

36" or 42" Wide Hood
42" or 48" for Island

}

For 36" Ranges

48", 54" or 60" Wide Hood
54" for Island

}

For 48" Ranges

Min. Distance Between Overhead Cabinets

of Combustible Material

30" Range – 30"
36" Range – 36"
48" Range – 48"

13" Max.

Cabinet

Depth

}

5" Min. to
combustible
side wall
material ,
(both sides)

18"

Min.

*35-7/8" Min. Range Height
with Leveling Legs fully
retracted
*36-3/4" Max. Range Height
with Leveling Legs fully
extended.

30" minimum from bottom of

overhead Hood to cooking

surface (36" min. if hood

contains combustible

materials )