Configuring Optional and Recommended UPS

7017 6300–005

6–51

Table 6–35. UPS Options

Component
Style Name

Interconnect Configuration and

Cable Part No.

Industry-Compatible UPS Systems

Notes

UPS915-WC6

15-Pin Male “D” to 9-Pin Male
(7015 5411-001)

Deltec 90S

1, 2, 7

9-Pin Male “D” to 9-Pin Male
(7015 6260-003)

Deltec 6000

1, 2, 7

Expansion Box Options

UPS111-EXP

Expansion Box for Variable Length
Cable

Any of the above

3, 7, 8

UPS5-EXP

Expansion Box with Fixed-Length
(5-Foot) Interconnect Cable

Any of the above located in the same cabinet
or adjacent (latched together) cabinet

4, 7

UPS1000-INT

UPS/SCJ Interconnect Box

None of the above. NUL (Japan) use only.

5, 7

UPS Interconnect Cables (One to One Cable)

CBL5-UPS

UPS Cable (5 ft), 7015 5403-000
9-Pin Female to 9-Pin Female

Any except UPS5-EXP
(contains 7015 5403-000)

6, 9

CBL10-UPS

UPS Cable (10 ft), 7015 5403-001
9-Pin Female to 9-Pin Female

Any except UPS5-EXP
(contains 7015 5403-000)

6

CBL15-UPS

UPS Cable (15 ft), 7015 5403-005
9-Pin Female to 9-Pin Female

Any except UPS5-EXP
(contains 7015 5403-000)

6

CBL25-UPS

UPS Cable (25 ft), 7015 5403-002
9-Pin Female to 9-Pin Female

Any except UPS5-EXP
(contains 7015 5403-000)

6

CBL50-UPS

UPS Cable (50 ft), 7015 5403-003
9-Pin Female to 9-Pin Female

Any except UPS5-EXP
(contains 7015 5403-000)

6

CBL100-UPS

UPS Cable (100 ft), 7015 5403-004
9-Pin Female to 9-Pin Female

Any except UPS5-EXP
(contains 7015 5403-000)

6

Notes:

1. Includes interconnect box (7016 0619-001), NT jumper cable assembly (7015 7789-000), and

configuration-specific adapter cable assembly.

2. One UPS interconnect cable (CBLxx-UPS) is required per UPS or add-on style

.

Must be ordered

separately.

3. Includes interconnect box (7016 0619-001) and NT jumper cable assembly (7015 7789-000)

.

Compatible with any of the interconnect configuration styles.

4. Includes interconnect box (7016 0619-001), NT jumper cable assembly (7015 7789-000), and 5-foot

UPS cable (CBL5-UPS).

5. Restricted to NUL (Japan) use

.

Includes interconnect box only.

6. See Table 6-36 to select proper cable length when going between SCP’s and servers.

7. The available UPS styles and expansion box options listed contain a NT jumper cable (7015 7789-

000) that connects to the NT server only (not used for SCP console). For additional NT server, order
UPS111-EXP.

8.

Order for additional NT server.

9.

Must be ordered separately when central site is used for dual SCP consoles.

The SCP jumper cable (7015 7789-001) and distribution box (7016 0619-001) used for the SCP
console is provided with the system under the primary and redundant console styles.