Om/sm-hy-6e(ce), 0 - maintenance, 0 - troubleshooting – Unified Brands HYPERSTEAM HY-6E(CE) User Manual

Page 13

Advertising
background image

OM/SM-HY-6E(CE) 1

OM/SM-HY-6E(CE)

13

7.0 - Maintenance

The HY-6E Steamer is designed for minimum
maintenance, and no user adjustments should be
necessary. Certain parts may need replacement
after prolonged use. If there is a need for service,
only Groen personnel or authorized Groen
representatives should perform the work.

Always supply water with a low mineral count that
meets the standards outlined in the Water
Conditioning
section of this manual.

The unit does not contain fuses that could be
replaced by the operator.

If steam or condensate is seen leaking from around
the door, take the following steps:

1. Check the door gasket. Replace if it is cracked or

split.

2. Inspect the cooking chamber drain to be sure

it is not blocked.

3. Adjust the latch pin to allow for changes that

might occur as the gasket ages:

a. Loosen the lock nut at the base of the

latch pin. Turn the latch pin ¼ turn
clockwise, and re-tighten the lock nut.

b. After adjustment, run the unit to test for

further steam leakage

c. If there is still leakage, repeat the

adjustment.

d. Continue adjusting the pin clockwise until

the door fits tightly enough to prevent
leakage.

8.0 - Troubleshooting

This Groen Steamer is designed to operate smoothly and efficiently if properly maintained. However, the following
is a list of checks to make in the event of a problem. Wiring diagrams are furnished inside the service panel. If an
item on the check list is marked with (X), it means that the work should be done by a factory-authorized service
representative.

SYMPTOM

WHO

WHAT TO CHECK

8.1 Steam generator does not fill

with water.

User

a. Is the ON switch depressed?
b. Is the water supply connected?
c. Is the water turned on?
d. Check for low water pressure (less than 30 PSI or

210 kPa).

e. Is the screen at the water connection clogged?
f.

Has the steam generator been delimed?

8.2 No steam.

User

a. Is the ON switch depressed?
b. Is the water supply connected?
c. Is the water turned on?
d. Are steamer doors open?
e. Is the steam generator limed up?

8.3 Red (SERVICE) light comes on

after four minutes.

User

a. Is the water supply connected?
b. Is the water turned on?
c. Has the unit been delimed? (Refer to Cleaning

Section)

8.4 Excessive steam escaping from

rear of unit

User

a. Is the water spray hose kinked or obstructed?

Auth Service
Rep Only

b. Is the water spray solenoid connected?(X)
c. Is the drain properly vented? (X)

Advertising