10.13

Supply Voltage Terminal Block - P/N 096810
Fuse - P/N 096809
Fuse 20 Amp - P/N 071489

1. Turn off the power to the steamer.

2. Remove the cover from the electrical compartment.

3. The terminal block is located on the back wall of the

electrical compartment.

4. Using a flat blade screwdriver, disconnect the

incoming wires from the top of the terminal block and
the steamer wires from the lower portion of the
terminal block.

5. With a wrench, remove the four 8-32 screws holding

the terminal block to the back wall.

To Install:

6. Position the new terminal block on the back wall and

install the four 8-32 screws using a wrench.

7. Using a flat blade screwdriver, connect the incoming

wires to the top of the terminal block, and the
steamer wires to the lower portion of the terminal
block.

10.14

Control Voltage Transformer
P/N 121716

1. Turn off power to the steamer.

2. Remove the front lower panel.

3. Using an open ended wrench, remove the four 1/4-20

bolts holding the electrical compartment to the
steamer table.

4. Disconnect the line side and the load side of the

electrical wires from their respective terminals.

5. Using a socket wrench with an extension, remove the

four 8-32 hex nut screws holding the transformer to
the floor of the electrical compartment.

To Install:

6. Position the transformer in the electrical

compartment.

7. Using a socket wrench with an extension, insert and

tighten the four 8-32 hex nut screws.

8. Connect the load and line side terminals.

10.15

Electrical Contactor

P/N 119811

1. Turn off power to the steamer.

2. Remove the front lower panel.

3. Using an open ended wrench, remove the four 1/4 -

20 bolts holding the electrical contactor to the
electrical compartment.

4. Unplug the line side and the load side terminals of the

contactor. Disconnect the control wires to the
contactor.

5. Using a socket wrench and extension, remove the

four 8-32 hex nut screws holding the contactor to the
floor of the electrical compartment.

To Install:

6. Position the contactor in the electrical compartment.

7. Using a socket wrench and extension, insert and

tighten the four 8-32 hex nut screws.

NOTE: The space is very restricted and it is helpful if the
nutdriver has a magnetic head to hold the screw in
position while it is being started.

8. Connect the load and line side terminals and the

control wires.

NOTE. The following components and subassemblies are
to be found in the upper portion of the steamer.

10.16 Timer Assembly

Timer Fastener Nut

P/N 100983

P/N 101145

1. Remove the four hex nuts which retain the control

panel cover. Remove the cover.

2. Remove the knob from the timer. Under the knob is a

hexagonal nut which holds the time mechanism to the
steamer. Note that there is a flat on the timer shaft
which corresponds to a frictional mounting hole on the
knob.

3. From the left side, unplug the five terminals/wires

(violet, gray, black, tan and white) from the timer
mechanism and unplug the two black timer motor
leads.

4. With an open-ended wrench, remove the hex nut

holding the timer in place. The timer may then be
removed from inside the compartment.

5. NOTE: Right below the timer shaft, the timer has a

small plastic disk molded onto the case. There is a

Advertising