Om/sm-hy-6e(ce) – Unified Brands HYPERSTEAM HY-6E(CE) User Manual

Page 30

Advertising
background image

0 OM/SM-HY-6E(CE)

OM/SM-HY-6E(CE)

30

1. Turn steamer off and allow it to cool.

2. Remove screws and U-channel from the door.

3. Remove screws, door handle, and cam.

4. Apply a NEVER-SEEZ high temperature compound

to the door cam and Locktite 242 to screw threads.

5. Assemble door cam to handle with screws.

6. Be sure door handle is in the DOWN position. Hold

U-channel door spring open with a screwdriver or
similar tool, then install the U-channel. Do NOT install
screws at this time

7. Check operation of the cam and door spring. Push

up on the door handle and check if spring opens. If
the spring does not open, the cam and spring are not
correctly aligned and the problem must be corrected.

8. Apply a light amount of Locktite 242 to screws, then

install screws.

10.28

Door Spring
P/N 078911

1. Turn off steamer and allow it to cool.

2. With flat blade screwdriver, remove two 8-32 truss

head screws on U-channel and remove U-channel
from door.

3. Carefully remove retaining ring from one end of

spring support pin, then remove the pin by moving
the pin to the left and to the right.

4. With a socket wrench, remove the 10-32 Keps nut,

lift the square plate, and then remove the spring.

To Install:

5. Apply a high temperature (rated 250ºC) anti-seize,

lubricating compound (NEVER-SEEZ) on the bottom
of the U-channel surface that connects with the
spring.

6. Install spring onto brass roller, then place square

plate over spring.

7. Apply Locktite 242 to Keps nut and install Keps nut.

8. Install spring support pin, then push the retaining ring

onto the pin using a screwdriver.

9. Hold door spring open with a screwdriver or similar

tool, hold door handle in the down position and install
the U-channel, top end first - then lower channel into

position. Check that spring opens when door handle is
pushed up.

10. Apply Locktite 242 to U-channel mounting screws,

then install the screws.

11. Replace the two 8-32 truss head screws in the U-

channel, applying Locktite 242 to secure them in
place.

10.29

Door Locking Pin
P/N 078914
Lock Nut
P/N 003823

1. Turn steamer off and allow it to cool

2. Note and record the distance between the lock nut

and the end of the (bullet shaped) door locking pin.
This information is important and will be needed for
installation.

3. Loosen lock nut and remove lock nut and door pin

(bullet) from front panel.

4. To install new door locking pin, coat locking pin

threads with NEVER-SEEZ high temperature
compound.

5. Install locking pin and lock nut. The lock nut to end-of-

bullet distance should be approximately the same as
measured above, in Step 2.

Advertising