Venmar HEPA 3100* User Manual

Page 9

Advertising
background image

- 9 -

1. Route the cable from the unit to a convenient location for the wall control.

2. Loosen the locking screw (the screw cannot be completely removed).

3. Detach the faceplate from the mounting plate by pulling the bottom part. If necessary, bore the mounting

holes and insert anchors.

4. Pass the cable (4 wires) through the opening of the mounting plate and mount the plate to the wall using

the provided screws.

5. Splice back the end of the cable to access to the 4 wires. Strip the end of each wire. Connect each wire

to its corresponding terminal: YELLOW wire to ‘’Y’’, RED wire to ‘’R’’, GREEN to ‘’G’’ and BLACK to ‘’B’’.
See illustration beside.

6. Reinstall the front module onto the back plate and tighten the locking screw.

CAUTION

Failure to comply with the following can cause erratic operation of the unit:

• Never install more than one optional wall control per unit.
• Keep control low voltage wiring at least 1 foot (305 mm) away from motors, lightning ballast, light dimming circuit and

power distribution panel. Do not route control wiring alongside electrical wires.

• Ensure the wires are securely connected.
• Disconnect power from the unit before removing the wall control faceplate from its mounting plate.

WARNING

Always disconnect the unit before making any connections. Failure in disconnecting power could result in electrical shock or
damage of the wall control or electronic module inside the unit.

!

4. WALL CONTROL INSTALLATION

VC0095