Maintenance/replacement parts – Vector Start-It VEC016 User Manual

Page 10

Advertising
background image

10

4.2

DC RECHARGE

Recharging the Main Unit from an external DC power source requires the use of the DC/DC

Recharge Cable. This cable has a DC connector at each end. See Figure 3B.

MAKE SURE SAFETY ON/OFF SWITCH AND WORKLIGHT ARE TURNED OFF

DURING RECHARGE, THIS MAY SLOW RECHARGE OF THE MAIN BATTERY.

Unlike the AC Recharge method, DC Recharge does not automatically activate the Battery

Status Display and provide a taper charge. To check the battery status, press the Battery Status

Display Pushbutton. If the Jump Starter’s battery is fully discharged, it is recommended that the

host vehicle or boat’s engine being used for recharging be left operating while the unit is being

charged using the 12 volt DC/DC method.

NOTE:

The DC recharge method will recharge the unit’s battery, but the green LED may not

light if the charging source is below 12.6 volts.AC recharge is the best method.

WARNING:

DO NOT RECHARGE MAIN UNIT FOR MORE THAN 3 HOURS MAXIMUM

USING 12 VOLT DC METHOD. DO NOT LEAVE UNIT UNATTENDED WHILE

DC CHARGING.

1. Insert the DC Plug of the DC Recharge Adapter into a DC Recharge/Accessory socket on the

unit.

2. Plug the other DC Plug into an accessory socket in a vehicle, power supply or other 12 volt

DC source.

3. Charge the unit until the green CHARGED indicator is lit when the Charge Status Button is

pressed - DO NOT EXCEED 3 HOURS MAXIMUM.

4. After charging, disconnect the cables and store them in the Cable Storage Hatch.

5.

MAINTENANCE/REPLACEMENT PARTS

For replacement parts (bulbs, batteries, charging adapters, etc.), contact Vector Technical

Support: (954) 584-4446 or toll free at 866-584-5504. Except a lamp in the worklight, there

are no user serviceable parts inside the unit. Periodically, the cables and connectors should be

inspected for damage, corrosion and dust and dirt. If surfaces are dirty, they can be wiped

clean with a cloth moistened with water and a drop of detergent. Contacts can be wiped clean

with a dry cloth.

WARNINGS:

OTHER THAN A BULB IN THE WORKLIGHT, THERE ARE NO USER SERVICABLE

PARTS INSIDE. DO NOT OPERATE UNIT IF THERE IS ANY EVIDENCE OF DAMAGE.THE

PRODUCT MUST BE RETURNED TO VECTOR FOR TESTING AND REPAIR. REPLACE ANY

DAMAGED CHARGING ADAPTERS IMMEDIATELY BEFORE FURTHER USE.

5.1

LAMP REPLACEMENT

You will need a small Phillips head type screwdriver and a “PR type” 12volt 0.2 ampere bulb.

1. Make sure the Work Light /area light is turned off.

2. Remove the two Phillips type screws (turn counter-clockwise).

3. Lift off lens and set it aside.

4. Using the clean cloth, rotate the burned out bulb until the bulb is in the position where the

reflector has a triangular gap.

5. Lift the bulb straight out.

NOTE:

DO NOT USE ANY METAL TOOLS TO REMOVE OR REPLACE BULB

6. Carefully replace with a new bulb (12 volt 0.2 amp bulb (type PR).

7. Rotate the bulb so the triangle gap and bulb are not aligned.

8. Snap the lens into place and replace the two screws.

9. Turn screws clockwise to tighten, being careful NOT TO OVER-TIGHTEN.

Advertising