2 mounting on a fixed roof tank, 1 top anchor method, Mounting on a fixed roof tank – Varec 4532 User Manual

Page 24: Top anchor method

Advertising
background image

Mounting

Average Temperature/Water Bottom Sensor and Converter

14

Installation and Operations Manual

5.2

Mounting on a fixed roof tank

There are three methods for mounting the 4532 ATC on a fixed roof tank:

Top anchor method

Thermo well method

Anchor weight method

If the tank bottom has a heating coil, the clearance from the flexible tube bottom hook

to the tank bottom may increase depending on the heating coil type.

5.2.1

Top anchor method

The flexible tube is stabilized by a wire hook and a top anchor.

Figure 5-2: Top anchor application

1. Insert a gasket and lower the flexible tube from the nozzle on the tank top.

Caution!

The flexible tube must be lowered carefully without bending too much and scratching
at the inner edge of the nozzle hole.

2. Rotate the 4532 ATC so that you can set up the cabling in the most convenient way.
3. Straighten the tensioning wire, fix the wire end to the top anchor temporarily and

lower the wire.

Electrical compartment

Cable entry as specified

Flange

Top anchor

Socket (1")

Tensioning wire

Flexible tube

approx.500 mm

From tank bottom to
element position #1

Clearance below

bottom hook

Ø26 mm(1.02")

400 mm (15.57")

Wire hook

(20")

Tank bottom

Advertising