15

TO TURN OFF GAS TO APPLIANCE

Clockwise

Continued

Figure 16 - Incorrect Pilot Flame Pattern

Thermocouple

Pilot Burner

Clockwise

INSPECTING

BURNER

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 15 shows a correct pilot flame pattern. Figure 16 shows an incorrect pilot
flame pattern. The incorrect pilot flame is not touching the thermocouple. This will
cause the thermocouple to cool. When the thermocouple cools, the heater will shut
down.

Figure 15 - Correct Pilot Flame Pattern

Thermocouple

Pilot Burner

Clockwise

Shutting Off Heater

1. Turn control knob clockwise

to the PILOT position.

2. Press in control knob and turn clockwise

to the OFF position.

3. Turn off all electric power to the appliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

1. Turn control knob clockwise

to the PILOT position.

MANUAL LIGHTING PROCEDURE

1. Remove front panel (see Figure 3, page 7).
2. Follow steps 1 thru 5 under LIGHTING INSTRUCTIONS, pages 13 and 14.
3. With control knob pressed in, strike match. Hold match to pilot until pilot lights.
4. Keep control knob pressed in for 30 seconds after lighting pilot. After 30

seconds, release control knob.

5. Replace front panel.

Advertising