Warning – Vanguard Heating VGN30 User Manual

Page 20

Advertising
background image

20

WARNING

!

WARNING ICON

G 001

If you smell gas

• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use

any phone in your building.

• Immediately call your gas supplier from a

neighbor’s phone. Follow the gas supplier’s
instructions.

• If you cannot reach your gas supplier, call the

fire department.

POSSIBLE
CAUSE

1. Metal expanding while

heating or contracting
while cooling

1. Heater burning vapors

from paint, solvents,
glues, etc.

2. Gas leak.

See Warn-

ing statement at
top of page

1. Not enough fresh air is

available

2. Low line pressure

3. ODS/pilot is partially

clogged

1. Gas leak.

See Warn-

ing statement at
top of page

2. Control valve defective

1. Foreign matter between

control valve and
burner

2. Gas leak.

See Warn-

ing statement at
top of page

OBSERVED
PROBLEM

Heater produces a
clicking/ticking noise
just after burner is lit or
shut off

Heater produces un-
wanted odors

Heater shuts off in use
(ODS operates)

Gas odor even when
control knob is in OFF
position

Gas odor during com-
bustion

REMEDY

1. This is common with

most heaters. If noise is
excessive, contact quali-
fied service person

1. Ventilate garage. Stop

using odor causing prod-
ucts while heater is run-
ning

2. Locate and correct all

leaks (see CHECKING
GAS CONNECTIONS,
page 11)

1. Open window and/or

door for ventilation

2. Contact local natural gas

company

3. Clean ODS/pilot (see

CLEANING AND
MAINTENANCE, page
17)

1. Locate and correct all

leaks (see CHECKING
GAS CONNECTIONS,
page 11)

2. Replace control valve

1. Take apart gas tubing

and remove foreign mat-
ter

2. Locate and correct all

leaks (see CHECKING
GAS CONNECTIONS,
page 11)

Advertising