Warning, Notice – Vanguard Heating VGN30 User Manual

Page 16

Advertising
background image

16

If pilot flame pattern is incorrect, as shown in Figure 16

• turn heater off (see TO TURN OFF GAS TO APPLIANCE, page 15)
• see TROUBLESHOOTING, pages 17 thru 20

BURNER FLAME PATTERN

Figure 17 shows a correct burner flame pattern. Figure 18 shows an incorrect
burner flame pattern. The incorrect burner flame pattern shows yellow tipping of
the flame. It also shows the flame higher than 1/2 the heat shield height.

CORRECT FLAME PATTERN

AT HIGH POSITION

1/2 HEAT
SHIELD HEIGHT

Figure 17 - Correct Burner Flame Pattern

1/2 HEAT
SHIELD HEIGHT

INCORRECT FLAME PATTERN

AT HIGH POSITION

Yellow
Tipping

Figure 18 - Incorrect Burner Flame Pattern

If burner flame pattern is incorrect, as shown in Figure 18

• turn heater off (see TO TURN OFF GAS TO APPLIANCE, page 15)
• see TROUBLESHOOTING, pages 17 thru 20

!

WARNING ICON

G 001

WARNING

If yellow tipping occurs, your heater could produce increased
levels of carbon monoxide. If burner flame pattern shows yellow
tipping, follow instructions at bottom of this page.

NOTICE

Do not mistake orange flames with yellow tipping. Dirt or other fine
particles enter the heater and burn causing brief patches of orange
flame.