OBSERVED
PROBLEM

Burner does not light
after ODS/pilot is lit
(continued from page
18)

Delayed ignition of
burner

Burner backfiring
during combustion

Yellow flame during
burner combustion

Slight smoke or odor
during initial opera-
tion

Heater produces a
whistling noise when
burner is lit

REMEDY

2. Replace burner orifice

3. Contact local natural gas

company

1. Contact local natural gas

company

2. Clean burner (see

CLEANING AND
MAINTENANCE, page
17) or replace burner ori-
fice

1. Clean burner (see

CLEANING AND
MAINTENANCE, page
17) or replace burner ori-
fice

2. Replace burner
3. Replace gas regulator

1. Check burner for dirt and

debris. If found, clean
burner (see CLEANING
AND MAINTENANCE,
page 17)

2. Replace gas regulator

1. Problem will stop after a

few hours of operation

1. Turn control knob to

LOW position and let
warm up for a minute

2. Operate burner until air is

removed from line. Have
gas line checked by local
natural gas company

3. Observe minimum instal-

lation clearances (see
Figure 2, page 6)

4. Clean burner (see

CLEANING AND
MAINTENANCE, page
17) or replace burner ori-
fice

POSSIBLE
CAUSE

2. Burner orifice diameter

is too small

3. Inlet gas pressure is too

low

1. Manifold pressure is too

low

2. Burner orifice is

clogged

1. Burner orifice is

clogged or damaged

2. Burner damaged
3. Gas regulator defective

1. Not enough air

2. Gas regulator defective

1. Residues from manu-

facturing processes

1. Turning control knob to

HIGH position when
burner is cold

2. Air in gas line

3. Air passageways on

heater blocked

4. Dirty or partially

clogged burner orifice