Owner’s manual, Troubleshooting, Continued – Vanguard Heating VDVF36PP User Manual

Page 25

Advertising
background image

25

105706

OWNER’S MANUAL

www.desatech.com

TROUBLESHOOTING

Continued

POSSIBLE CAUSE

1. Ignitor electrode not connected to igni-

tor cable

2. Ignitor cable pinched or wet

3. Piezo ignitor nut is loose

4. Broken ignitor cable
5. Bad piezo ignitor
6. Ignitor electrode broken
7. Ignitor electrode positioned wrong

1. Gas supply turned off or manual shutoff

valve closed

2. Control knob not in PILOT position
3. Control knob not pressed in while in

PILOT position

4. Air in gas lines when installed

5. Depleted gas supply (propane/LP

models only)

6. Pilot is clogged
7. Gas regulator setting is not correct

1. Control knob not fully pressed in
2. Control knob not pressed in long enough

3. Manual shutoff valve not fully open
4. Pilot flame not touching thermocouple,

which allows thermocouple to cool,
causing pilot flame to go out. This prob-
lem could be caused by one or both of
the following:
A) Low gas pressure
B) Dirty or partially clogged pilot

5. Thermocouple connection loose at con-

trol valve

6. Thermocouple damaged
7. Control valve damaged

REMEDY

1. Reconnect ignitor cable

2. Free ignitor cable if pinched by any

metal or tubing. Keep ignitor cable dry

3. Tighten nut holding piezo ignitor. Nut

is located behind the mounting bracket

4. Replace ignitor cable
5. Replace piezo ignitor
6. Replace pilot assembly
7. Replace pilot assembly

1. Turn on gas supply or open manual

shutoff valve

2. Turn control knob to PILOT position
3. Press in control knob while in PILOT

position

4. Continue holding down control knob.

Repeat igniting operation until air is
removed

5. Contact local propane/LP gas company

6. Clean pilot or replace pilot assembly
7. Replace gas control

1. Press in control knob fully
2. After pilot lights, keep control knob

pressed in 30 seconds

3. Fully open manual shut-off valve
4. A) Contact local gas company

B) Clean pilot or replace pilot assembly

5. Hand tighten until snug, then tighten

1/4 turn more

6. Replace thermocouple
7. Replace control valve

OBSERVED PROBLEM

When ignitor button is pressed, there is no
spark at pilot

When ignitor button is pressed, there is
spark at pilot but no ignition

Pilot lights but flame goes out when control
knob is released

Continued

Advertising
This manual is related to the following products: