Owner’s manual, Venting installation, Continued – Vanguard Heating VDVF36PP User Manual

Page 9

Advertising
background image

9

105706

OWNER’S MANUAL

UP

UP

VENTING
INSTALLATION

Continued

(Framing

Detail)

10"

(254mm)

10"

(254mm)

7 1/2"

(190mm)

Vent Opening

Combustible Wall

Vent Opening

Non-Combustible Wall

Figure 17 - Vent Opening Requirements

Continued

3.

Attach vent pipe assembly to the fire-
place. Set fireplace in front of it’s per-
manent location to insure minimum
clearances. Mark the wall for a 10"
square hole (for noncombustible ma-
terial such as masonry block or con-
crete, a 7

1

/

2

" diameter hole is accept-

able). See Figure 17. The center of the
hole should line up with the center-
line of the horizontal rigid vent pipe.
Cut a 10"x10" (254mm x 254mm)
square hole through combustible ex-
terior wall (7

1

/

2

" [190mm] diameter

hole if noncombustible). Frame as nec-
essary (see Figure 17).

Figure 19 - Installing Vinyl Siding Standoff

Cut Vinyl Siding
Away to Fit
Standoff

Wood Screw

Nut

Bolt

Standoff

Vent Cap

Figure 16 - Vent Pipe Connections

Female
Locking
Lugs

Male
Slots

Rigid Vent Pipe Flexible Vent Pipe

Spacer
Spring

4" Clamp

7" Clamp

4" Flex
Pipe

7" Flex
Pipe

Apply Mastic
to All Four Sides

Figure 18 - Installing Horizontal Vent Cap

Wood
Screw

Vent Cap

Apply Mastic
to All Four
Sides

WARNING: Do not recess vent

termination in to any wall. This
will cause a fire hazard.

4.

Apply a bead of non-hardening mastic
around the outside edge of the vent cap.
Position the vent cap in the center of
the 7

1

/

2

" or 10" hole on the exterior

wall with the arrow on the vent cap
pointing up. Insure proper clearance of
1" to combustibles is maintained. At-
tach the vent cap with four wood screws
supplied (see Figure 18).

Note

: Re-

place the wood screws with appropri-
ate fasteners for stucco, brick, concrete,
or other types of siding.

For vinyl siding use vinyl siding stand-
offs between vent cap and exterior wall.
The vinyl siding standoff prevents ex-
cessive heat from melting the vinyl sid-
ing material. Bolt the vent cap to the
standoff. Apply non-hardening mastic
around outside edge of the standoff in-
stead of the vent cap assembly. Use
wood screws provided to attach the
standoff. See Figure 19.

5.

Slide the wall thimble over the vent pipe
before connecting the horizontal run to
the vent cap (see Figure 20).

6.

Carefully move the fireplace with vent
assembly attached toward the wall and
insert the vent pipe into the horizontal
termination. The pipe overlap should be
a minimum of 1

1

/

4

". Apply silicone to

the connection. Fasten all vent connec-
tions with screws provided. Refer to
Framing on pages 4 and 5 for instruc-
tions on securing unit to framing or floor.

7.

Slide the wall thimble against the inte-
rior wall surface and attach with screws
provided (see Figure 20).

Vent Cap
(Horizontal
Termination)

Interior Wall
Surface

Wall
Thimble

Horizontal
Vent Pipe

Figure 20 - Connecting Vent Cap with
Horizontal Vent Pipe

Screw