Performing Calibration

Note: This step is very important and must always be carried out whenever

media is being changed. Failure to do so will result in mis-detection of

the label size.

1. Press and hold the “PAUSE” button.

2. Turn on power.

3. When the message “CALIBRATION” is displayed on the LCD, both READY

and MEDIA indicators will blink. At this point, release the button.

4. The printer will then feed 12 inches of label media.

5. When the “READY” message is displayed, the READY and MEDIA indicators

will stop blinking and remain illuminated.

Printing Configuration Report

1. Turn off the printer. Press and hold the FEED button.

2. Turn on the power.

3. When the message “SELF TESTING....” is displayed on the LCD and the

READY indicator blinks, then release the button.

4. The printer will print out a configuration report.

5. When the “READY” message is displayed and the READY indicator stops

blinking and lights up, then the following information will be printed:

• Font list

• DIP switch settings

• Hardware configuration status

• Label parameters

• Firmware version