Waterford TARA T25 Direct Vent Freestanding Gas Stove

INSTALLATION

RIGID PIPE VENTING - VERTICAL TERMINATIONS

for both Residential & Manufactured Homes/Mobile Homes

The shaded areas in the two diagrams below show all allowable combinations of straight vertical and offset to vertical runs with
vertical terminations.
Maximum t w o 45

o

elbows (not including the 45

o

elbow attached to the unit.). All vertical and offset to vertical

vent installations require Vent Restrictor #1. If the vent is ENCLOSED in a chase (min. size 9" x 9") maintain a 1-1/4" clearance to combustibles.

Offset to Vertical Terminations

Vent Restrictor must be set at 5/8" for this venting installation.

Straight Vertical

Terminations

RIGID PIPE VENTING -

HORIZONTAL TERMINATIONS

The shaded area in the diagram below shows all allowable combinations
of vertical runs with horizontal terminations. Maximum one 90

O

elbow

(two 45

o

elbows equal one 90

o

elbow) using Dura-Vent Venting Systems

Residential and Manufactured Homes /

Mobile Homes Installations

The venting arrangements diagrammed below, have a minimum of 75% (flue loss)
efficiency with Fan Off, as required for manufactured homes. (Actual efficiency
may be as high as 85%.)